منابع مشابه
Accelerated idioventricular rhythm associated with desflurane anesthesia
571 Received: October 9, 2008. Accepted: December 31, 2008. Corresponding author: Hong-Seuk Yang, M.D., Department of Anesthesiology and Pain Medicine, University of Ulsan College of Medicine, Asan Medical Center, 388-1, Pungnap-2dong, Songpa-gu, Seoul 138-736, Korea. Tel: 82-23010-3865, Fax: 82-2-470-1363, E-mail: [email protected] Copyright c Korean Society of Anesthesiologists, 2009 Accele...
متن کاملDesflurane why this choice?
1. It should have a rapid and smooth onset of action. Efficiency is a particularly important factor in the ambulatory setting [1] 2. There should be a rapid recovery of cognitive functioning without clinically-significant discomfort. Postoperative pain is a major limiting factor in determining when a patient can be discharged home after surgery. 3. The absence of adverse effects such as nausea ...
متن کاملIranian Elderly Experiences With Myocardial Infarction
Objectives: Awareness of elderly patients' experiences of myocardial infarction can assist to identify their need, problems, as well as promote their quality of lives. However, there is a little information about how elderly people experience myocardial infarction. This study aimed to explore elderly patients experience with myocardial infarction and their coping strategies. Methods & Materi...
متن کاملReproducible hepatic dysfunction following separate anesthesia with sevoflurane and desflurane.
Both desflurane and sevoflurane have individually been reported to induce hepatic dysfunction; however hepatic dysfunction after administration of both of them separately in a single patient has not previously been reported. As their metabolites differ in nature, we considered that it would be unlikely that their combined use would cause sensitization and induce hepatic dysfunction. We report o...
متن کاملThe desflurane Tec 6 vaporizer.
A late development model of the Tec 6 vaporizer for the administration of desflurane vapour has been evaluated. It is heated electrically and has both electronic monitors of vaporizer function and alarms. The new filling system is a significant improvement over previous Tec filling systems. The vaporizer requires a warm-up period before it may be used, but when activated it provides an output t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Anaesthesia
سال: 2007
ISSN: 0003-2409,1365-2044
DOI: 10.1111/j.1365-2044.1994.tb03498.x