Experience with parallel optical link for the CDF silicon detector
نویسندگان
چکیده
منابع مشابه
Initial experience with the CDF layer 00 silicon detector
We report on initial experience with the Collider Detector at Fermilab (CDF) Layer 00 Detector. Layer 00 is an innovative, low-mass, silicon detector installed in CDF during the upgrade for Run 2A of the Tevatron. Noise pickup present during operation at CDF is discussed. An event-by-event pedestal correction implemented by CDF is presented. This off-line solution prevents L00 from being used i...
متن کاملSVX’, the new CDF silicon vertex detector
The Collider Detector at Fermilab (CDF) radiation hardened silicon vertex detector (SVX’) is described. The new detector has several improvements over its predecessor such as better signal to noise and higher efficiency. It is expected to have a radiation tolerance in excess of 1 Mrad. It has been taking data for several months and some preliminary results are shown.
متن کاملProgress in the construction of the CDF silicon vertex detector
The mechanical design and construction progress of the CDF silicon vertex detector is described. Results on the location accuracy of the silicon strip detectors are presented and indicate an initial placement uncertainty of less than 10 Wm. The water and gas cooling system, which is constructed of low mass materials and is used to remove heat from the readout electronics, is briefly described ....
متن کاملThe CDF Run IIb silicon detector: Design, preproduction, and performance
A new silicon microstrip detector was designed by the CDF collaboration for the proposed high-luminosity operation of the Tevatron pp̄ collider (Run IIb). The detector is radiation-tolerant and will still be functional after exposure to particle fluences of 10 1-MeV equivalent neutrons=cm and radiation doses of 20MRad. The detector will maintain or exceed the performance of the current CDF silic...
متن کاملStatus and Performance of the CDF Run II Silicon Detector
The CDF Run II silicon detector with its 8 layers of doubleand single-sided silicon micro strip sensors and a total 722,432 readout channels is one of the largest silicon detector devices currently in use by a HEP experiment. We report our experience commissioning and operating this complex device during the first 4 years of Run II. As the luminosity delivered by the Tevatron collider increases...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
سال: 2003
ISSN: 0168-9002
DOI: 10.1016/s0168-9002(03)01785-6