Exergy of heat flows of the air-to-air plate heat exchanger
نویسندگان
چکیده
منابع مشابه
Exergy Analysis of an Air Dehumidification System Equipped with Mixing Box and Heat Exchanger Heat Recovery Units
Exergy analysis emboldens in cases that all the inefficiencies and bottlenecks to improve energy systems are to be addressed. In this study, a novel vapor compression air dehumidifier integrated with an auxiliary heat exchanger in series arrangement with the main condenser in order to mitigate the reheat coil, and an extra mixing box to recover the ventilated air heat has been introduced. A com...
متن کاملHeat transfer enhancement due to air bubble injection into a horizontal double pipe heat exchanger
If an air flow is injected into a liquid fluid, many ambulant air bubbles are formed inside the fluid. Air bubbles move inside the liquid fluid because of the buoyancy force, and the mobility of these air bubbles makes sizable commixture and turbulence inside the fluid. This mechanism was employed to enhance the heat transfer rate of a horizontal double pipe heat exchanger in this paper. Howeve...
متن کاملPassive Energy Air-to-Water Heat Pipe Based Heat Exchanger and its Potential of Air Pre-cooling in Air Conditioning Systems for Iran Climate
Air pre-cooling equipment is normally being employed in air-conditioning systems for pre-cooling the ambient outdoor air to enhance the air-conditioning systems performance. In this study, the potential of a passive water-to-air heat pipe based heat exchanger (HPHEX) for air pre-cooling purpose in air-conditioning systems for the high cooling load demanding regions of Iran was investigated. To ...
متن کاملAir-side Particulate Fouling of Microchannel Heat Exchangers: Experimental Comparison of Air-Side Pressure Drop and Heat Transfer with Plate-Fin Heat Exchanger
In this study, the air-side pressure drop and heat transfer performance of plate-fin and microchannel coils were tested under clean and fouled conditions. The heat exchangers were tested with two different types of dust, ASHRAE dust and Arizona Road Test Dust. The ASHRAE dust was found to have a very significant impact on the pressure drop of the microchannel heat exchanger, increasing the air-...
متن کاملExperimental Study of Heat Transfer Rate in a Shell and Tube Heat Exchanger with Air Bubble Injection (TECHNICAL NOTE)
Shell and tube heat exchangers are widely being used in many of industrial and power engineering applications. Different techniques have been employed in order to enhance the performance of the heat exchanger. Air bubble injection is one method to increase the turbulence of the flowing fluids which in turn enhance the heat transfer performance. Injecting air bubbles is one of the promising tech...