Exergy and Exergoeconomic Analyses of Air Conditioning Applications Integrated with an Air Membrane Exchanger
نویسندگان
چکیده
The results obtained from the exergoeconomic and exergy analysis of a model generic air conditioning (A/C) system without with an membrane exchanger using three commercially available refrigerants: R410A, R407C, R134a, are reported. used specialized software that was validated against recently published data showed good agreement. A/C systems energy intensive consume significant portion global electricity. Improving their efficiency by even small amount will produce considerable savings, reduce running costs, lower pollution emissions. same A/c investigated for different ambient temperatures, relative humidities (RHs), pressure ratios compressor. It shown inclusion improved all refrigerants tested, particularly at higher temperature. Both coefficient performance exergetic reduced increase in ratio due to increasing fuel losses. In components except one, it found source cost is inefficiencies; hence, expense non-exergy improve effectiveness entire system.
منابع مشابه
Evaluation of an Integrated Cryogenic Natural Gas Process with the Aid of Advanced Exergy and Exergoeconomic Analyses
In this study, an integrated structure of the air separation unit, natural gas liquids recovery equipped with nitrogen removal unit is developed. In this regard, advanced exergy and exergoeconomic analyses are used to examine the irreversibility, possible improvements and the cost of the inefficiencies of the process. The exergy analysis presents information on the origin of the irreversibility...
متن کاملExergy Analysis of an Air Dehumidification System Equipped with Mixing Box and Heat Exchanger Heat Recovery Units
Exergy analysis emboldens in cases that all the inefficiencies and bottlenecks to improve energy systems are to be addressed. In this study, a novel vapor compression air dehumidifier integrated with an auxiliary heat exchanger in series arrangement with the main condenser in order to mitigate the reheat coil, and an extra mixing box to recover the ventilated air heat has been introduced. A com...
متن کاملPassive Energy Air-to-Water Heat Pipe Based Heat Exchanger and its Potential of Air Pre-cooling in Air Conditioning Systems for Iran Climate
Air pre-cooling equipment is normally being employed in air-conditioning systems for pre-cooling the ambient outdoor air to enhance the air-conditioning systems performance. In this study, the potential of a passive water-to-air heat pipe based heat exchanger (HPHEX) for air pre-cooling purpose in air-conditioning systems for the high cooling load demanding regions of Iran was investigated. To ...
متن کاملAn Experimental Study of Nanofluids Operated Shell and Tube Heat Exchanger with Air Bubble Injection
Shell and Tube heat exchangers are the heat exchangers that are most widely used in industries and for other commercial purposes. There are many techniques that have been utilized to enhance the heat transfer performance of the shell and tube heat exchangers. Air bubble injection is one of the promising and inexpensive techniques that can create turbulence in the fluids resulting in to enhancem...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Processes
سال: 2022
ISSN: ['2227-9717']