Exergy Analysis of Transcritical CO2 Air-Source Heat Pump with Honeycomb Gas Cooler
نویسندگان
چکیده
In order to build an efficient and energy-saving CO2 heat pump system improve the transfer efficiency of gas cooler, a novel honeycomb cooler with compact structure, high efficiency, pressure-bearing capacity was proposed in our previous work. To clarify components that need further optimization its performance, exergy analysis transcritical air-source is studied this paper. Based on second law thermodynamics, model each component established, irreversible loss analyzed. addition, degree energy clarified, possibility direction are pointed out. The results show 35.33% under nominal operating conditions, there lot room for improvement utilization. three largest destruction percentage compressor, throttle valve, evaporator 36.13%, 22.90%, 19.51%, respectively. These percentages main reasons large losses system.
منابع مشابه
Field Evaluation for Air-source Transcritical CO2 Heat Pump Water Heater with Optimal Pressure Control
Several optimal discharge pressure correlations for transcritical CO2 heat pump in literature have been discussed in this paper. Most of them are related to the ambient temperature, the evaporation temperature and the gas cooler outlet temperature. A revised optimal discharge pressure model as the function of ambient temperature and water outlet temperature is developed based on earlier experim...
متن کاملThermoeconomic optimization and exergy analysis of transcritical CO2 refrigeration cycle with an ejector
The purpose of this research is to investigate thermoeconomic optimization and exergy analysis of transcritical CO2 refrigeration cycle with an ejector. After modeling thermodynamic equations of elements and considering optimization parameters of emerging temperature of gas of cooler (Tgc) , emerging pressure of cooler's gas (Pgc) , and eva...
متن کاملThermoeconomic optimization and exergy analysis of transcritical CO2 refrigeration cycle with an ejector
The purpose of this research is to investigate thermoeconomic optimization and exergy analysis of transcritical CO2 refrigeration cycle with an ejector. After modeling thermodynamic equations of elements and considering optimization parameters of emerging temperature of gas of cooler (Tgc) , emerging pressure of cooler's gas (Pgc) , and eva...
متن کاملExergy, Economic and Environmental Analyses of Gas Turbine Inlet Air Cooling with a Heat Pump Using a Novel System Configuration
Gas turbines incur a loss of output power during hot seasons due to high ambient air temperatures, and input air cooling systems are often used to partly offset this problem. Here, results are reported for an investigation of the utilization of a heat pump to cool the inlet air of a gas turbine compressor. The analyses are carried out for two climates: the city of Yazd, Iran, which has a hot, a...
متن کاملthermoeconomic optimization and exergy analysis of transcritical co2 refrigeration cycle with an ejector
the purpose of this research is to investigate thermoeconomic optimization and exergy analysis of transcritical co2 refrigeration cycle with an ejector. after modeling thermodynamic equations of elements and considering optimization parameters of emerging temperature of gas of cooler (tgc) , emerging pressure of cooler's gas (pgc) , and evaporative temperature (tevp) , optimization of targ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Buildings
سال: 2023
ISSN: ['2075-5309']
DOI: https://doi.org/10.3390/buildings13092147