Exergy Analysis of Air Conditioning (AC) System in Suite Room Santika Hotel Yogyakarta

نویسندگان

چکیده

Abstract Air Conditioning are major contributors to energy consumption in-suite room Santika Hotel Yogyakarta. A suite is a choice of rooms with the best facilities compared other rooms, so comfort one services that must be optimized. The ain determine conduction heat load various components in room. Heat calculation includes through glass on east 1253.18 BTU/hr, wall south 606.14 solar radiation 1268.48 gain from people 1980 electrical equipment/lights 2193 BTU/hr and ventilation 13053.6 BTU/hr. total amount used exergy analysis value 3053.16

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Exergy Analysis of a Dual-mode Refrigeration System for Ice Storage Air Conditioning

This paper introduces the dual-mode refrigeration system for ice storage air conditioning. A computational model relating to the exergy loss amount and loss rate is developed in each component of the refrigeration cycle loop. A case study is presented to demonstrate the applicability of the model developed. Exergy analysis results of the refrigeration system in ice storage operating mode are co...

متن کامل

Design and Implementation of Air Conditioning System in Operating Room

The system is air conditioning system in operating room. The main objective of the system was implemented to provide air balance and temperature necessary conditions and to control airflow system for ventilation units in operating room. The operation room can be controlled with fuzzy expert system and describes the desired outputs. Input parameters such as temperature, humidity, oxygen and part...

متن کامل

Exergy and Thermoeconomic Analysis for an Underground Train Station Air-Conditioning Cooling System

The necessity of air-conditioning causes the enormous energy use of underground train stations. Exergy and thermoeconomic analysis is applied to the annual operation of the air-conditioning system of a large underground train station in Taiwan. The current installation and the monitored data are taken to be the base case, which is then compared to three different optimized designs. The total re...

متن کامل

Exergy Analysis in Hydrogen-Air Detonation

The main goal of this paper is to analyze the exergy losses during the shock and rarefaction wave of hydrogen-air mixture. First, detonation parameters pressure, temperature, density, and species mass fraction are calculated for three cases where the hydrogen mass fraction in air is 1.5%, 2.5%, and 5%. Then, exergy efficiency is used as objective criteria of performance evaluation. A two-dimens...

متن کامل

Energy Saving System for Air Conditioning of Clean Room for Semiconductor Factory (Estimation of FMU System)

The total power consumption of all semiconductor plants exceeds 100 million kWh per year, with about 43% of this consumption to operate air conditioning facilities. This high power consumption is due to the requirement of the cleanliness kept for clean rooms, with extremely high power consumed to the air transferring power. Oki developed the fan module unit (FMU) type air conditioning system to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IOP conference series

سال: 2021

ISSN: ['1757-899X', '1757-8981']

DOI: https://doi.org/10.1088/1755-1315/927/1/012043