Exergoeconomic and Exergetic Sustainability Analysis of a Combined Dual-Pressure Organic Rankine Cycle and Vapor Compression Refrigeration Cycle
نویسندگان
چکیده
In this paper, an exergoeconomic and exergetic sustainability analysis of a dual-pressure organic Rankine cycle (ORC) vapor compression refrigeration (VCRC) driven by waste heat is performed for power generation cooling production. addition, the most suitable fluid couple among thirty-five different pairs was investigated proposed combined system. The results indicate that highest energy utilization factor, exergy efficiency, system coefficient performance, net are calculated R123-R141b pair. terms indicators, best performance obtained combination. minimum unit electricity cost shortest payback period as 0.0664 $/kWh 2.5 years, respectively, R123-R290 component with destruction boiler, 21.67%. result parametric showed thermodynamic parameters increase increment ORC’s boiling temperature. increasing temperature, environmental effect factor decreases, while index increases. Additionally, temperature increases, total production decrease. It suggested to use created thermodynamic, analysis.
منابع مشابه
The energy and exergy analysis of a novel cogeneration organic Rankine power and two-stage compression refrigeration cycle
The energy crisis in recent years has led to the use of thermodynamic cycles that work based on renewable energies. Low-temperature cycles—such as organic cycles—are suitable strategies for the application of renewable energies. The present study proposes a novel cycle through the integration of a two-stage compression refrigeration cycle with a combined Rankine power and ejector refrigerat...
متن کاملDynamical modeling and thermo-economic optimization of a cold room assisted vapor-compression refrigeration cycle
A cold room assisted vapor-compression refrigeration cycle is dynamically modeled in a year and optimized. Total annual cost (TACO) and coefficient of performance (COP) are selected as two objective functions. Both cold room and refrigeration cycle parameters are considered as design variables. Moreover, three working fluids included R22, R134a and R407c are examined. The optimum Pareto front r...
متن کاملParametric and working fluid analysis of a combined organic Rankine-vapor compression refrigeration system activated by low-grade thermal energy
The potential use of many common hydrofluorocarbons and hydrocarbons as well as new hydrofluoroolefins, i.e. R1234yf and R1234ze(E) working fluids for a combined organic Rankine cycle and vapor compression refrigeration (ORC-VCR) system activated by low-grade thermal energy is evaluated. The basic ORC operates between 80 and 40 °C typical for low-grade thermal energy power plants while the basi...
متن کاملUsing Carbon Dioxide in a Transcritical Vapor Compression Refrigeration Cycle
For most of the last fifty years, refrigeration and heat pump systems have been based on cycles using a fluorocarbon as the working fluid. Hovvever, with the discovery that fluorocarbons may have a profoundly detrimental effect on the earth ·s atmosphere. it has become necessary to find a suitable replacement for a fluorocarbon based refrigeration cycle. Such a replacement must perform comparab...
متن کاملParametric Assessment of a Novel Geothermal Multi-Generation Equipped with Dual-Organic Rankine Liquefied Natural Gas Regasification Cycle Using Advanced Exergy and Exergoeconomic-Based Analyses
This research is concerned with the design and analysis of a geothermal based multi-generation system by applying both conventional and advanced exergy and exergoeconomic concepts. The proposed energy system consists of a dual-organic Rankine cycle (ORC) to vaporize liquefied natural gas (LNG) and produce electricity. A proton exchange membrane(PEM) electrolyzer is employed to produce hydrogen ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Sustainability
سال: 2023
ISSN: ['2071-1050']
DOI: https://doi.org/10.3390/su15086987