Ex-PRESS Shunt Extrusion upon Globe Palpation

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impending extrusion of Ex-PRESS shunt treated by shunt-position adjustment: a case report

BACKGROUND To report a case of impending extrusion of Ex-PRESS shunt treated by shunt-position adjustment. CASE PRESENTATION A 56-year-old Asian woman presented with impending extrusion and malposition of Ex-PRESS shunt in her left eye. The bleb of the left eye was shallow and diffuse. In the past, the patient was treated by Ex-PRESS shunt implantation under the scleral flap in both eyes. The...

متن کامل

Ex-PRESS miniature glaucoma shunt in treatment of refractory glaucoma.

Refractory glaucoma in a complicated type of glaucoma of different ethyologies with one same characteristic--intraocular pressure of great resistance to therapy. There are different methods of treatment in such glaucomas, primary surgical options. Ex-PRESS miniature glaucoma shunt implantation was our treatment of choice. In our group of patients we achieved stabile intraocular pressure values ...

متن کامل

Surgical treatment of neovascular glaucoma with Ex-PRESS glaucoma shunt

RATIONALE Neovascular glaucoma (NVG) is one of the most aggressive types of glaucoma, and its abnormal fibrovascular tissue growth on the iris and trabecular meshwork may create difficulties to control the intraocular pressure (IOP) and perform the operation such as trabeculectomy. PATIENT CONCERNS Ex-PRESS glaucoma shunt has been introduced to serve as one alternative operation for glaucoma,...

متن کامل

Clinical experience with Ex-press Mini Glaucoma Shunt implantation.

In this prospective study we wanted to report our experience and to evaluate the efficacy and safety of Ex-press Mini-Glaucoma Shunt implantation under a superficial scleral flap, as a newly and improved surgical technology in a treatment of POAG (Primary open-angle glaucoma) and refractory glaucoma. 44 eyes (35 patients) underwent an implantation of Ex-Press Mini Glaucoma Shunt. We had 21 pati...

متن کامل

Globe Extrusion(Sever Globe Tenting ) Due to Trauma

A 13 year-old boy crashed into a car while riding his bicycle and his right face and orbit were traumatized, then immediately globe extruded completely, his outward appearance was terrible when he was hospitalized, and the vision was NLP. Optic nerve, muscles, and all vessels and nerves were in severe stretching and the globe was at risk of ischemia and necrosis. I.V. corticosteroid, antibiotic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Ophthalmology

سال: 2018

ISSN: 0161-6420

DOI: 10.1016/j.ophtha.2018.07.025