Evolved Fuzzy Control System for a Steam Generator

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evolved Fuzzy Control System for a Steam Generator

Poor control of steam generator water level is the main cause of unexpected shutdowns in nuclear power plants. Such shutdowns are caused by violation of safety limits on the water level and are common at low operating power where the plant exhibits strong nonminimum phase characteristics. In addition, the steam generator is a highly complex, nonlinear and time-varying system and its parameters ...

متن کامل

Steam Generator Water Level Control: a Hybrid System Approach

The Mixed Logical Dynamical (MLD) formalism is an efficient modeling framework for hybrid systems which allows formulating and solving problems such as moving horizon predictive control and state estimation. This paper presents the application of the combined strategies – state estimation for fault detection and predictive control for water level control – to a steam generator benchmark modeled...

متن کامل

An Evolved Fuzzy Reactive Control System

Autonomous robots operating in unstructured environments clearly require some capacity for adaptive behaviour. This paper presents a method for achieving an adaptive response based on a multi-layer control architecture. The primary level of control is composed of the Behaviour Synthesis Architecture [1] which is continuously modified by a secondary layer, composed of a Fuzzy Logic controller. T...

متن کامل

A MEMS Steam Generator

Previous work [1] has shown that MEMS technology has significant potential to create more compact, higherperforming hardware for chemical oxygen iodine lasers (COIL). In COILs, the laser medium is a flowing gas that must be pumped through the system at high mass flow rates to ensure proper system operation. As a result, compact pumps with high pumping rates are a key element of the COIL system....

متن کامل

An EMAT System for Detecting Flaws in Steam Generator Tubes

The detection of flaws in steam generator tubing is often made difficult by environmental considerations. The small diameter, 7/8 inch (2.2 cm), long, 70 feet (21.3m), tubes occur in large bundles with access only being possible from the inside of the end of each tube. Furthermore, inspection must be fully automatic when the steam generator is part of a nuclear power plant because of radiation ...

متن کامل