SiGeC Cantilever Micro Cooler
The fabrication and characterization of SiGeC cantilever microcoolers are described. Silicon on insulator (SOI) was used as the substrate, and two layers of 3 μm p-SiGe0.07C0.0075 and 1.14 μm n-SiGe0.07C0.0075 lattice matched to silicon were grown using molecular beam epitaxy. The uni couple cooler was fabricated using conventional integrated circuit (IC) processing, and the cantilever structur...
متن کامل10K Pulse Tube Cooler
A 3-stage pulse tube cooler has been designed to operate at 10¶K. The staged cooler uses the same compressor and parallel staging configuration for the 1 st and 2 nd stages as previously employed for our delivered High Capacity Cryocooler (HCC). The 2 nd and 3 rd stages are in a serial configuration. The addition of the third stage extends the performance of this cooler to lower operating tempe...
متن کاملA Cooler Raman Laser
P ower dissipation, which results in heat generation in electronic chips, is the number one difficulty facing the semiconductor industry. The problem is so severe that it threatens to halt the huge development that has been enjoyed since the microprocessor industry’s inception — a doubling in processor performance roughly every 18 months, which was predicted by the celebrated Moore’s law. And t...
متن کاملSolid-State Cooler: New Opportunities
The idea of engineering cooling systems and generators based on thermal transformations and energy conversion in solids has been exciting scientific minds already for several decades. In recent years, a possibility of coolers production based on the electrocaloric effect (ECE) began to become of special interest [1]. This interest is related to the substantial progress made in investigations of...
متن کاملMass Measurement of 56Sc Reveals a Small A = 56 Odd-Even Mass Staggering, Implying a Cooler Accreted Neutron Star Crust.
We present the mass excesses of (52-57)Sc, obtained from recent time-of-flight nuclear mass measurements at the National Superconducting Cyclotron Laboratory at Michigan State University. The masses of 56Sc and 57Sc were determined for the first time with atomic mass excesses of -24.85(59)((-54)(+0)) MeV and -21.0(1.3) MeV, respectively, where the asymmetric uncertainty for 56Sc was included ...