Evaluation the Effect of Photon Beam Energies on Organ at Risk Doses in Three-Dimensional Conformal Radiation Therapy
نویسندگان
چکیده
منابع مشابه
Evaluation the Effect of Photon Beam Energies on Organ at Risk Doses in Three- Dimensional Conformal Radiation Therapy
As regards, the selection of appropriate energy in radiotherapy tumors that are placed in non-homogen areas is important, so the aim of the present study is evaluating the effect of 6 and 15MV photon beam energies on dose distribution in 3D-CRT for lower esophageal and rectal cancers. 12 patients with lower esophageal cancer and 12 patients with rectal cancer respectively, with the prescription...
متن کاملRespiratory motion effect on tumor and normal tissue doses in patients with lung cancer, treated with Intensity Modulation Radiation Therapy and Three Dimensional Conformal Radiation Therapy.
Introduction: The aim of this study is to investigate the effect of respiratory motion during radiation therapy in patient with lung cancer and comparison of dosimetric parameters between Intensity modulation radiation therapy and three-dimensional conformal radiotherapy in lung cancer. Materials and Methods: Two CT scan was performred for each pati...
متن کامل3D-Conformal Radiation Therapy and Intensity-Modulated Radiation Therapy Techniques for Laryngeal Cancer Taking Parotid Glands as Organ at Risk
Background: Three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) techniques are used for the treatment of patients with laryngeal cancer. Objective: This study aimed to investigate the effects of these 2 treatment techniques on the planning target volume (PTV) (laryngeal cancer), dose homogeneity, dose of organs at...
متن کاملComparison of three different techniques in parotid gland tumors using three dimensional conformal radiation therapy
Introduction: Background: Radiotherapy of parotid tumors is achieved by different radiotherapy techniques. So they deliver the dose to organs at risk such as contralateral parotid, temporal lobe & spinal cord. The consequences of high dose to OARs are xerostomia, Temporal lobe necrosis and loss of hearing. Purpose: The aim of this study was to compare different treatment tech...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Research Journal of Applied Sciences, Engineering and Technology
سال: 2013
ISSN: 2040-7459,2040-7467
DOI: 10.19026/rjaset.6.3833