Evaluation of thermal performance of air source heat pump heating system based on electricity equivalent

نویسندگان

چکیده

Thermal performance assessment and optimization for energy conversion utilization systems are of high significance in building efficiency. Generally speaking, the evaluation actual thermodynamic system is mainly based on First law thermodynamics, with emphasis quantity consumption, while ignoring quality. Thus, it results a one-sided analysis saving. In this paper, electricity equivalent used to analyse evaluate air source heat pump heating under different working conditions. Moreover, dynamic thermal performances three typical space devices (radiator, fan coil, radiant floor) investigated compared by weighing both The show that COP radiator, floor 3.00, 3.82, 4.76, coefficient quality 48.32%, 51.43%, 50.57%, respectively. However, robustness its lower than radiator coil. This work can provide reference guidance practical design systems.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance Assessment of a Variable Capacity Air Source Heat Pump and a Horizontal Loop Coupled Ground Source Heat Pump System

This study evaluates the performance of air source heat pump (ASHP) and ground source heat pump (GSHP) systems individually and as part of their associated heating and cooling distribution systems in two semi-attached houses. Over the monitoring period, the performance of both heat pumps exceeded manufacturer and EnerGuide ratings, with Coefficients of Performance (COPs) above 5 in the cooling ...

متن کامل

Study on the Performance of a Ground Source Heat Pump System Assisted by Solar Thermal Storage

A ground source heat pump system (GSHPS) utilizes a relatively stable underground temperature to achieve energy-saving for heating and cooling in buildings. However, continuous long-term operation will reduce the soil temperature in winter, resulting in a decline in system performance. In this research, in order to improve the system performance of a GSHPS, a ground heat pump system integrated ...

متن کامل

Analysis of Electricity Usage for Domestic Heating Based on an Air-To-Water Heat Pump in a Real World Context

In this paper a new computational model to estimate the performance of an air to water heat pump in relation to outdoor temperatures is proposed and evaluated. This model is an extension and refinement of a model proposed in previous work. In the new model the following has been taken into account. Real empirical data for usage of a heat pump over a whole heating season have been used to obtain...

متن کامل

Performance Comparison of Hydronic Secondary Loop Heat Pump and Conventional Air-Source Heat Pump

In residential heat pump systems, the motivation for secondary loop systems is to allow for the use of flammable or toxic refrigerants with lower global warming potentials than the currently employed HFC refrigerants. The addition of radiant panels as integral building components (embedded in concrete at construction or attached to the underside of wood flooring) is becoming more common. Combin...

متن کامل

Modelling The Performance Of A Domestic Low-Temperature Heating System Based On A Heat Pump

Low temperature heating systems for single-family houses, based on heat pumps are becoming progressively more preferable in the global market. The possibility of such systems to optimise the energy utilisation and to achieve a high annual energy efficiency make them more promising for future low energy houses. In this study we model and analyse the performance of a low temperature heating syste...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Thermal Science

سال: 2022

ISSN: ['0354-9836', '2334-7163']

DOI: https://doi.org/10.2298/tsci210712006h