Evaluation of the Seismic Response Parameters for Infilled Reinforced Concrete Frame Buildings

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Soil Structure Interaction in the Analysis and Seismic Design of Reinforced Concrete Frame Buildings

The influence of soil-structure interaction in the analysis and design of a 6-storey and basement reinforced concrete frame building is investigated. Models simulating two different conditions: namely soil-structure interaction, and fixed-base behavior are considered. The influence of the soil structure interaction in the dynamic behavior of the structure is reflected in an increase in the vibr...

متن کامل

Evaluation of Seismic Vulnerability of Reinforced Concrete Buildings Adjacent to the Deep Excavations

In this study, the effect of deep excavation on the seismic response of RC moment resisting building systems has been studied. Deep excavation can cause significant changes in the stress and strain levels of soil environment and also changes in the propagation of seismic waves. This leads to permanent displacements in the foundation system. In this study, three RC building systems, i.e. 5, 10, ...

متن کامل

Probabilistic assessment of the seismic damage in reinforced concrete buildings

The main objective of this article is to assess the expected seismic damage in reinforced concrete buildings from a probabilistic point of view by using Monte Carlo simulation. To do that, the seismic behavior of the building is studied by using random capacity obtained by considering the mechanical properties of the materials as random variables. Starting from the capacity curves, one can obta...

متن کامل

experimental investigation of masonry infilled reinforced concrete frame

an experimental study is conducted on three ½ scales, single-story, single-bay, frame specimens. the first specimen was a reinforced concrete frame with solid-brick infill. the second specimen was a reinforced concrete frame with hollow clay perforated-brick infill. the last specimen was a reinforced concrete frame without any infill. these three specimens were tested by pseudostatic method. di...

متن کامل

Seismic Response of Reinforced Concrete Columns

There are a large number of reinforced concrete buildings in seismically active areas of the world that are not built in accordance with modern seismic design provisions such as those published by American Concrete Institution ([ACI] Committee 318, 2008). In the United States and other parts of the developed world, these buildings were constructed between 1930s to mid 1970s according to the bui...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IOSR Journal of Mechanical and Civil Engineering

سال: 2017

ISSN: 2320-334X,2278-1684

DOI: 10.9790/1684-1401032841