Evaluation of Stress Distribution Using Advanced Photon Source
نویسندگان
چکیده
منابع مشابه
hazard evaluation of gas condensate stabilization and dehydration unit of parsian gas refinery using hazop procedures
شناسایی مخاطرات در واحد 400 پالایشگاه گاز پارسیان. در این پروزه با بکارگیری از تکنیک hazop به شناسا یی مخاطرات ، انحرافات ممکن و در صورت لزوم ارایه راهکارهای مناسب جهت افزایش ایمنی فرا یند پرداخته میگردد. شرایط عملیاتی مخاطره آمیز نظیر فشار و دمای بالا و وجود ترکیبات مختلف سمی و قابل انفجار در واحدهای پالایش گاز، ضرورت توجه به موارد ایمنی در این چنین واحدهایی را مشخص می سازد. مطالعه hazop یک ر...
Magnetic Performance of Insertion Devices at the Advanced Photon Source
The insertion devices (IDs) at the Advanced Photon Source have been magnetically tuned to minimize the integrals of the field through the devices and to minimize the variation of those integrals with gap, with a goal of not perturbing the stored particle beam. Measurements of the particle beam motion as the ID gap was changed found that the closed-orbit distortion was better than the requiremen...
متن کاملEmittance Measurements of the Advanced Photon Source Photocathode Rf Gun*
The Advanced Photon Source (APS) photocathode rf gun is the primary beam source for the APS Low-Energy Undulator Test Line (LEUTL) free-electron laser (FEL) experiment. In the current operating regime of LEUTL, peak current has been the dominant factor in determining FEL performance. As LEUTLs operational wavelength is reduced, however, the beam emittance will play an increasingly important ro...
متن کامل*Radiation Effects Studies at the Advanced Photon Source
At the Advanced Photon Source (APS) concern for radiation-induced demagnetization of the insertion devices (IDs) in the storage ring and in the free-electron laser has initiated systematic radiation effects studies towards the development of efficient techniques for ID protection. The studies include radiation dose monitoring, parametric study of the radiation-induced demagnetization, as well a...
متن کاملHigh-Precision Positioning Mechanism Development at the Advanced Photon Source
There are many challenging tasks in the design of the beamline instrumentation that relate to high precision positioning mechanism for users at a third-generation synchrotron radiation source, such as the 7 GeV Advanced Photon Source (APS). Over the last few years, progress has been made in the development of novel mechanisms with high positioning resolution and high stability at the APS. Appli...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Marine Engineering
سال: 2009
ISSN: 1346-1427,1884-3778
DOI: 10.5988/jime.44.744