Evaluation of SrAl 2 O 4 :Eu, Dy phosphor for potential applications in thermoluminescent dosimetry
نویسندگان
چکیده
منابع مشابه
el combustion synthesis and luminescence properties of nanoparticles of onoclinic SrAl 2 O 4 : Eu 2 + , Dy 3 +
Nanoparticles of strontium aluminate phosphors co-a tivated by Eu2+ and Dy3+ have been prepared by heating theprecursorsobtained fromnitrate salt–ammoniumacetic–urea–gel combustionprocess at temperature of 1150 ◦C in a weak reductive atmosphere of thermal carbon. Transmission electronmicroscope
متن کاملCalculation of the thermal conductivity of L 2 SrAl 2 O 7 ( L = La , Nd , Sm , Eu , Gd , Dy )
Jing Feng,1,2 Chunlei Wan,1 Bing Xiao,3 Rong Zhou,2 Wei Pan,1,* and David R. Clarke4 1State Key Laboratory of New Ceramics and Fine Processing, Department of Materials Science and Engineering, Tsinghua University, Beijing 100084, P. R. China 2Key Laboratory of Advanced Materials of Precious-Nonferrous Metals, Education Ministry of China, Kunming University of Science and Technology, Kunming 650...
متن کاملMechanoluminescence of Ba2 MgSi2 O7 doped with Eu(2+) and Dy(3+) phosphor by impulsive deformation.
Di-barium magnesium silicate phosphor doped with Eu(2+) and Dy(3+) was prepared using a solid-state reaction technique under a reducing atmosphere. The sample underwent impulsive deformation by impact from a piston for mechanoluminescence (ML) investigations. The temporal ML characteristics of the phosphor were observed, which expressed a single sharp peak with a long decaying period. To invest...
متن کاملPercentage depth dose evaluation in heterogeneous media using thermoluminescent dosimetry
The purpose of this study is to investigate the influence of lung heterogeneity inside a soft tissue phantom on percentage depth dose (PDD). PDD curves were obtained experimentally using LiF:Mg,Ti (TLD-100) thermoluminescent detectors and applying Eclipse treatment planning system algorithms Batho, modified Batho (M-Batho or BMod), equivalent TAR (E-TAR or EQTAR), and anisotropic analytical alg...
متن کاملCounting the Photons: Determining the Absolute Storage Capacity of Persistent Phosphors
The performance of a persistent phosphor is often determined by comparing luminance decay curves, expressed in cd/m 2 . However, these photometric units do not enable a straightforward, objective comparison between different phosphors in terms of the total number of emitted photons, as these units are dependent on the emission spectrum of the phosphor. This may lead to incorrect conclusions reg...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Applied Clinical Medical Physics
سال: 2021
ISSN: 1526-9914,1526-9914
DOI: 10.1002/acm2.13251