EVALUATION OF SOIL STIFFNESS USING PERFORMANCE CURVES OF AN EIGHT-STORY STEEL-REINFORCED CONCRETE BUILDING WITH EMBEDDED SPREAD FOUNDATION

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Seismic Performance of Steel Plate-Reinforced Concrete Composite Shear Wall

In tall buildings the reinforced concrete (RC) shear wall is one of the predominant structural components used to resist lateral loads induced by earthquakes around the world. Previous research demonstrated that shear walls displayed a sudden loss in lateral capacity due to the wall corner and web crushing in the plastic zone. In addition, it was found that large shear distortions in shear wall...

متن کامل

Performance Evaluation of an FRP-Reinforced Concrete Bridge

As part of a larger project to investigate the use of Fiber-Reinforced Polymer (FRP) materials in bridge construction, a short-span FRP-reinforced concrete bridge was installed in central Missouri. The Walters Street Bridge is a precast concrete panel bridge reinforced with both glass FRP (GFRP) and carbon FRP (CFRP) reinforcing bars. It was designed according to the American Concrete Institute...

متن کامل

A Study of the Apparent Change in the Foundation Response of a Nine-story Reinforced Concrete Building by Douglas

Forced vibration tests of the Millikan Library building, a nine-story reinforced concrete shear-wall structure, were conducted in 1966 and 1967, before the San Fernando earthquake, and again in 1974. The measured foundation response of the structure reported for the two tests was significantly different: in the earlier tests, motion of the foundation in the N-S direction contributed only about ...

متن کامل

Strength and Toughness of Reinforced Concrete with Coated Steel Fibers

The effect of zinc phosphate (ZP) and zinc calcium phosphate (ZCP) coatings on the reinforcing mechanisms of smooth steel fiber in cementitious matrix have been studied. The results of pull out tests illustrated that by coating smooth steel fiber the pull-out load may be increased up to 100%. The effect of zinc phosphate coating on interface bonding was more than zinc-calcium phosphate coating....

متن کامل

Effect of column-foundation connection stiffness on seismic performance of rocking steel braced frame

Residual drifts after severe earthquakes interrupt serviceability of buildings. Retrofitting of such buildings is in many cases very difficult and consumes lots of time and money. Recently, there are some attempts to develop the seismic design procedures to not only satisfy life safety criteria but also lead to more economical buildings. One of these modern methods of improving seismic performa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Structural and Construction Engineering (Transactions of AIJ)

سال: 2015

ISSN: 1340-4202,1881-8153

DOI: 10.3130/aijs.80.609