Evaluation of P/M Alloy 625-clad Steel Pipe.
نویسندگان
چکیده
منابع مشابه
Corrosion Behavior of Stainless Steel Clad Rebar
Stainless steel clad rebar (SCR) was investigated because it may become a cost-effective means of controlling corrosion in concrete under very aggressive environments. Sound SCR (316L cladding) resisted corrosion in saturated Ca(OH)2 solution (SCS) with up to 5 wt% chloride. Cladding breaks on SCR induced significant corrosion of exposed underlying CS in SCS with only 1 wt% chloride. A computer...
متن کاملOxidation Performance of Platinum-Clad Mo-47Re Alloy
The alloy Mo-47Re has favorable mechanical properties at temperatures above 1400 C, but it undergoes severe oxidation when used in air with no protective coating. To shield the alloy from oxidation, platinum cladding has been evaluated. The unprotected alloy undergoes catastrophic oxidation under static and dynamic oxidation conditions. The platinum cladding provides good protection from static...
متن کاملClinical evaluation of 625 lacunar syndrome patients
A lacuna is an area of infarction within the territory of a single perforated artery. Lacuna patients may present with numerous clinical syndromes. Lacunae typically present with highly focal brain symptoms (1). The clinical expression of lacunar infarcts is related to their location. Lacunae are more frequent in the basal ganglia, internal capsule, pons, and corona radiate (1); therefore, cort...
متن کاملLaser clading of Inconel 625 on ASTM A575 steel
In this research, the microstructure of Inconel 625 cladded layer on ASTM A575 steel has been investigated. By examining different parameters, the optimal single-pass sample with the least amount of dilution, porosity and fusion and suitable wetting angle was determined. Then cladding process with the optimal parameter was performed. The microstructure of the cladding layer was evaluated from t...
متن کاملLaser clading of Inconel 625 on ASTM A575 steel
In this research, the microstructure of Inconel 625 cladded layer on ASTM A575 steel has been investigated. By examining different parameters, the optimal single-pass sample with the least amount of dilution, porosity and fusion and suitable wetting angle was determined. Then cladding process with the optimal parameter was performed. The microstructure of the cladding layer was evaluated from t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Japan Society of Powder and Powder Metallurgy
سال: 1992
ISSN: 0532-8799,1880-9014
DOI: 10.2497/jjspm.39.701