Evaluation of Madurahydroxylactone as a Slow Release Antibacterial Implant Coating
نویسندگان
چکیده
منابع مشابه
Evaluation of Madurahydroxylactone as a Slow Release Antibacterial Implant Coating
Madurahydroxylactone (MHL), a secondary metabolite with antibacterial activity was evaluated for its suitability to generate controlled drug release coatings on medical implant materials. A smooth and firmly attached layer could be produced from a precursor solution on various metallic implant materials. In physiological salt solutions these coatings dissolved within a time period up to one wee...
متن کاملA decomposable silica-based antibacterial coating for percutaneous titanium implant
Although percutaneous titanium implants have become one of the best choices as retainers in the facial defects, peri-implantitis still occurs at a significant rate. This unwanted complication occurs due to adhesion of bacteria and subsequent biofilm formation. To solve this problem, we have developed a novel antibiotic nanodelivery system based on self-decomposable silica nanoparticles. In this...
متن کاملEvaluation of a novel slow-release paclitaxel-eluting stent with a bioabsorbable polymeric surface coating.
OBJECTIVES We sought to evaluate a new second-generation drug-eluting stent (DES), comprising a slow-release biodegradable polylactide coglycolide (PLGA) polymer and low-dose paclitaxel on a thin-strut cobalt chromium stent platform, in a clinically relevant animal model. BACKGROUND Our previous work demonstrated subacute vascular toxicity and necrosis triggering late excess neointima in pig ...
متن کاملThin magnesium layer confirmed as an antibacterial and biocompatible implant coating in a co-culture model
Implant-associated infections commonly result from biofilm‑forming bacteria and present severe complications in total joint arthroplasty. Therefore, there is a requirement for the development of biocompatible implant surfaces that prevent bacterial biofilm formation. The present study coated titanium samples with a thin, rapidly corroding layer of magnesium, which were subsequently investigated...