Evaluation of Lightning Outage Rate Considering Line Surge Arrester Failure

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sensitivity Assessment of Lightning Protection Device Aging Effect on Distribution Substation Insulation

 Insufficient electrical endurance of equipment and insulation failure against overvoltage is one of the most effective reasons for failure the power line. Lightening, switching or other disruptive parameters can cause line outage or distribution substation failure. There are different devices used to improve the safety, reliability, and power quality of the system. Surge arresters are one of t...

متن کامل

Performance of Surge Arrester to Multiple Lightning Strokes on Nearby Distribution Transformer

Overhead distribution lines are prone to lightning overvoltages due to their configurations and characteristics. Metal Oxide Varistor (MOVs) arresters for many years have proven to be more advantageous than others arresters in lightning surge protection; therefore it is worthwhile to continually assess the behavior and performance of these arresters to different kind of overvoltages caused by l...

متن کامل

Surge Arrester Simulation in Fourier Transients Programs of Transmission Systems

The importance of simulating surge arresters in fast transients programs stems from their useful property as a means of controlling switching overvoltages in EHV and UHV systems. The paper proposes a surge arrester model to be used in conjunction with a transient program based on Fourier transform technique. The validity of the proposed model is demonstrated by computational results.

متن کامل

Metal-oxide surge arrester model for fast transient simulations

Metal-oxide surge arresters have dynamic characteristics that are significant for overvoltage coordination studies involving fast front surges. Several models with acceptable accuracy have been proposed to simulate this frequency-dependent behavior. Difficulties arise in the calculation and adjustment of the model parameters: in some cases iterative procedures are required, in others the necess...

متن کامل

Implementation of a Transmission Line Model with the PEEC Method for Lightning Surge Analysis

This paper proposes a simple transmission line model adopted with the partial element equivalent circuit (PEEC) method for lightning surge analysis. The proposed approach is employed for calculating tower surge responses and voltages across insulators of an actual transmission tower. The proposed approach increases the efficiency of the method in terms of computation time because of reducing a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEJ Transactions on Power and Energy

سال: 2005

ISSN: 0385-4213,1348-8147

DOI: 10.1541/ieejpes.125.723