Evaluation of interlocking intramedullary nailing in distal tibial fractures and nonunions
نویسندگان
چکیده
منابع مشابه
The Role of Biplanar Distal Locking in Intramedullary Nailing of Tibial Shaft Fractures
Background: To compare the union times of the uncomplicated tibial shaft fractures, which were distally locked by twocoronal and one sagittal screws and by only two coronal screws.Methods: 45 patients with tibial shaft treated with intramedullary nailing included in this study. 23 of 45 fractureswere treated with uniplanar two distal interlocking (Group 1) and 22 fractures were treated with bip...
متن کاملUnreamed intramedullary nailing with oblique proximal and biplanar distal interlocking screws for proximal third tibial fractures.
PURPOSE To assess the outcome of unreamed intramedullary nailing through the lateralised entry point using oblique proximal and biplanar distal interlocking screws. METHODS 15 men and 3 women aged 25 to 58 (mean, 37) years underwent unreamed intramedullary nailing with oblique proximal and biplanar distal interlocking screws for proximal third metaphyseal tibial fractures. The entry point was...
متن کاملIntramedullary nailing and angulation prevention in distal metaphyseal tibial fractures.
Intramedullary nailing, which is preferred in tibial diaphyseal fractures, is also frequently used in distal third tibial fractures. Various angular deformities, including varus/valgus deformity, may be observed during postintramedullary nailing. Orthopedic surgeons use several methods to prevent this problem.In this study, at least 2 static locking screws were placed proximal and distal to the...
متن کاملDistal Locking Screws for Intramedullary Nailing of Tibial Fractures.
Recently introduced tibial intramedullary nails allow a number of distal screws to be used to reduce the incidence of malalignment and loss of fixation of distal metaphyseal fractures. However, the number of screws and the type of screw configuration to be used remains obscure. This biomechanical study was performed to address this question. Thirty-six Expert tibial nails (Synthes, Oberdorf, Sw...
متن کاملReamed interlocking intramedullary nailing for the treatment of tibial diaphyseal fractures and aseptic nonunions. Can we expect an optimum result?
The need for reaming and the number of locking screws to be used in intramedullary (IM) tibial nailing of acute fractures as well as routine bone grafting of tibial aseptic nonunions have not been clearly defined. We describe the results of reamed interlocked IM nails in 233 patients with 247 tibial fractures (190 closed, 27 open and 30 nonunions). Ninety-six percent of the fractures were unite...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Acta Orthopaedica et Traumatologica Turcica
سال: 2009
ISSN: 1017-995X
DOI: 10.3944/aott.2009.472