Evaluation of image lag in a flat‐panel, detector‐equipped cardiovascular X‐ray machine using a newly developed dynamic phantom

We developed a dynamic phantom for use in routine checks. This phantom can be used to physically evaluate image lag that occurs in dynamic images. It has a unique measurement method. ROIs on the target are chosen, and, with the position of ROIs fixed on the image, changes in pixel value are detected physically when the target passes through the ROIs over time and perceived as image lag. Thus, i...

متن کامل

AbstractID: 14240 Title: Efficacy of a linear lag correction algorithm in an a-Si flat-panel x-ray detector

ID: 14240 Title: Efficacy of a linear lag correction algorithm in an a-Si flat-panel x-ray detector Purpose: Lag in a-Si flat-panel detectors (FPD) causes significant artifact. To date, most correction models have assumed a linear, time-invariant model (LTIM). We investigated detector response as a function of incident exposure. Method and Materials: The physics theory for charge trapping in FP...

متن کامل

Evaluation of patient exposure with Flat Panel Detector (FPD) in X-ray TV system

The use of flat-panel detector (FPD) systems in TV equipment for gastrointestinal tract examination is increasing. The use of FPD systems is believed to reduce the exposure dose. When our institution changed its TV equipment from an image intensifier (GE;MS90Tj) system to an FPD (Shimadzu;SONIALVISION safire DAR-3500) system, we measured the doses produced and carried out a comparative examinat...

متن کامل

Development of a cardiac evaluation method using a dynamic flat-panel detector (FPD) system: a feasibility study using a cardiac motion phantom.

The purpose of this study is to investigate the feasibility of cardiac evaluation with a dynamic flat-panel detector (FPD), based on changes in pixel values during cardiac pumping. To investigate the feasibility of cardiac evaluation with a dynamic flat-panel detector (FPD), based on changes in pixel values during cardiac pumping. Sequential radiographs of a cardiac motion phantom and water-equ...

متن کامل

Title Pulmonary blood flow evaluation using a dynamic flat - panel detector

Purpose Pulmonary ventilation and circulation dynamics are reflected on fluoroscopic images as changes in X-ray translucency. The purpose of this study was to investigate the feasibility of non-contrast functional imaging using a dynamic flat-panel detector (FPD). Methods Dynamic chest radiographs of 20 subjects (Abnormal, n=12; Normal, n=8) were obtained using the FPD system. Image analysis wa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Applied Clinical Medical Physics

سال: 2015

ISSN: 1526-9914

DOI: 10.1120/jacmp.v16i2.5213