Evaluation of Half-Cell Potential Measurements for Reinforced Concrete Corrosion

نویسندگان

چکیده

The evaluation of half-cell potential measurements in reinforced concrete (RC) members can be a key issue for civil engineers. primary reason this is that the interpretation based on available standards provides information related only to possibility corrosion concrete, but it does not provide clear perception influence capacity RC members. objective study two-fold: (1) explore level flexural members; and (2) engineers with better understanding correlation between To establish this, twelve beams were cast then exposed accelerated utilizing an impressed current. After that, tests performed entire surface beams. Next, four-point loading test was determine their behavior. analysis showed there high positive tested which demonstrates predict degradation due corrosion.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Obtaining Effective Half-Cell Potential Measurements in Reinforced Concrete Structures

Corrosion of steel reinforcement is a major factor in the deterioration of highway and bridge infrastructure. A survey of the condition of a reinforced concrete structure is the first step towards its rehabilitation. A rapid, cost-effective and non-destructive condition survey offers key information on the evaluation of corrosion, and aids in the quality assurance of concrete repair and rehabil...

متن کامل

Methodology for Assessing the Probability of Corrosion in Concrete Structures on the Basis of Half-Cell Potential and Concrete Resistivity Measurements

In recent years, the corrosion of steel reinforcement has become a major problem in the construction industry. Therefore, much attention has been given to developing methods of predicting the service life of reinforced concrete structures. The progress of corrosion cannot be visually assessed until a crack or a delamination appears. The corrosion process can be tracked using several electrochem...

متن کامل

Effect of Water-cement Ratio on Corrosion of Reinforced Concrete

Corrosion of reinforced concrete is one of the major problems in the construction industry causing premature deterioration of concrete structures well before their service life. This has placed incredible financial burden on many projects and also placed safety of users at risk. A research work was carried out to evaluate the effect of water cement ratio on corrosion of steel in reinforced conc...

متن کامل

Corrosion Monitoring of Reinforced Concrete Structures - A Review

Reinforced concrete structures have the potential to be very durable and capable of withstanding a variety of adverse environmental conditions. However, failures in the structures do still occur as a result of premature reinforcement corrosion. The maintenance and repair of bridges and buildings for their safety requires effective inspection and monitoring techniques for assessing the reinforce...

متن کامل

Monitoring Corrosion of Steel Bars in Reinforced Concrete Structures

Corrosion of steel bars embedded in reinforced concrete (RC) structures reduces the service life and durability of structures causing early failure of structure, which costs significantly for inspection and maintenance of deteriorating structures. Hence, monitoring of reinforcement corrosion is of significant importance for preventing premature failure of structures. This paper attempts to pres...