Evaluation of Different Methods for Non-Metric Camera Calibration
نویسندگان
چکیده
منابع مشابه
Influence Factors Evaluation on High-precision Planar Calibration of Non-metric Digital Camera
With the rapid development of three-dimensional (3D) modelling, camera calibration is paid more and more attention. In this article, we analyse the influence factors in the calibration: the camera and lens, the shape of control points, photography model and the scale between calibration object and measurement. Appropriate model can get the right result quickly, and the position of the model in ...
متن کاملDistributed Metric Calibration of Large Camera Networks
Motivated by applications in surveillance sensor networks, we present a distributed algorithm for the automatic, external, metric calibration of a network of cameras with no centralized processor. We model the set of uncalibrated cameras as nodes in a communication network, and propose a distributed algorithm in which each camera only communicates with other cameras that image some of the same ...
متن کاملdevelopment of different optical methods for determination of glucose using cadmium telluride quantum dots and silver nanoparticles
a simple, rapid and low-cost scanner spectroscopy method for the glucose determination by utilizing glucose oxidase and cdte/tga quantum dots as chromoionophore has been described. the detection was based on the combination of the glucose enzymatic reaction and the quenching effect of h2o2 on the cdte quantum dots (qds) photoluminescence.in this study glucose was determined by utilizing glucose...
Sensors for 3D Imaging: Metric Evaluation and Calibration of a CCD/CMOS Time-of-Flight Camera
3D imaging with Time-of-Flight (ToF) cameras is a promising recent technique which allows 3D point clouds to be acquired at video frame rates. However, the distance measurements of these devices are often affected by some systematic errors which decrease the quality of the acquired data. In order to evaluate these errors, some experimental tests on a CCD/CMOS ToF camera sensor, the SwissRanger ...
متن کاملSimple Calibration Techniques for Non-metric Cameras
ABSTRACT Architectural documentation is carried out mostly with (analogue or digital) non-metric cameras or video-cameras. Unknown internal geometry is a main problem in this context, particularly for wide-angle lenses with their considerable amount of distortion. Self-calibrating bundle adjustment or 3D test-field calibration may provide straightforward answers to this problem, yet on occasion...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Anuário do Instituto de Geociências - UFRJ
سال: 2020
ISSN: 0101-9759,1982-3908
DOI: 10.11137/2020_1_266_272