Evaluation of different counting methods for use in radiochemical purity testing procedures for 99mTc-labelled radiopharmaceuticals
نویسندگان
چکیده
منابع مشابه
Influence of Storage Temperature on Radiochemical Purity of 99mTc-Radiopharmaceuticals.
The influence of effective room temperature on the radiochemical purity of 99mTc-radiopharmaceuticals was reported. This study was born from the observation that in the isolators used for the preparation of the 99mTc-radiopharmaceuticals the temperatures can be higher than those reported in the commercial illustrative leaflets of the kits. This is due, in particular, to the small size of the wo...
متن کاملPitfalls in the Standard Radiochemical Purity Testing for Technetium·99m·Exametazime
Objective: The purpose of this study was to examine discrepancies in the standard method for determining the radiochemical purity (RCP) of mTc-exametazime. The package insert for mrc-exametazime indicates that the entire RCP testing procedure requires approximately 15 min to complete, although the solvent-developing time for the three-paper chromatography system is described to be s 1 00 sec. A...
متن کاملdevelopment of different optical methods for determination of glucose using cadmium telluride quantum dots and silver nanoparticles
a simple, rapid and low-cost scanner spectroscopy method for the glucose determination by utilizing glucose oxidase and cdte/tga quantum dots as chromoionophore has been described. the detection was based on the combination of the glucose enzymatic reaction and the quenching effect of h2o2 on the cdte quantum dots (qds) photoluminescence.in this study glucose was determined by utilizing glucose...
Determination of the radiochemical purity of 99mTc- tetrofosmin: Comparison between five methods
METHODS: Nineteen vials of tetrofosmin were radiolabelled with Tc and the percentages of the RCP were determined. Five different methods were compared with the standard RCP testing method (ITLC-SG, 2x20 cm): Whatman 3MM (1x10 cm) with acetone and dichloromethane (method 1); Whatman 3MM (1x10 cm) with ethyl acetate (method 2); aluminum oxide-coated plastic thin-layer chromatography (TLC) plate (...
متن کاملParticle-size and radiochemical purity evaluations of filtered 99mTc-sulfur colloid prepared with different heating times.
UNLABELLED Sentinel node lymphoscintigraphy using colloidal particles has become common practice at many institutions. The ideal particle size for colloids such as filtered (99m)Tc-sulfur colloid ((99m)Tc-FSC) in sentinel node studies is 15-100 nm. It is reported that the use of a reduced heating time during the reconstitution process results in an increased number of smaller particles (<30 nm)...