EVALUATION OF CRACK DEPTH IN REINFORCED CONCRETE STRUCTURE USING ULTRASONICS

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Crack Depth Measurement in Concrete Using Surface Wave Transmission

A technique to estimate the depth of surface-breaking cracks in concrete is presented. The surface wave transmission coefficient across the crack plane is determined and used to estimate the depth. A self-compensating testing scheme is applied to eliminate experimental difficulties. Here the self-compensating testing scheme is introduced, and the approach used to estimate crack depth from the m...

متن کامل

prediction method of drying shrinkage crack in reinforced concrete walls

because thin plate reinforced concrete members such as walls and slabs are greatly influenced by the drying shrinkage, cracks can occur in these members due to the restraint of the volume change caused by drying shrinkage. therefore, the control of cracking due to drying shrinkage is very important in building construction that the thin plate members are frequently used. however, few researches...

متن کامل

Crack Detection and Classification in Concrete Structure

This paper presents crack detection in concrete structure based on fuzzy logic. Safety inspection of concrete structures is very important since it is closely related with the structural health and reliability. Automated structural health monitoring system becomes necessity in recent years that encourages various researches to be going on in this area. Cheap availability of digital cameras make...

متن کامل

Quasi Distributed OTDR Crack Sensor for Reinforced Concrete Structures

A quasi-distributed fiber optic sensor is developed for embedment in concrete structures. The sensor principles are simple, and therefore, practical for crack detection and deformation measurement in civil structural applications. The distributed sensor developed herein operates based on the intensity measurements of optical power. The sensor consists of a number of individual segments on one l...

متن کامل

Ultrasound diffusion for crack depth determination in concrete.

The determination of the depth of surface-breaking cracks in concrete specimens using an ultrasound diffusion technique is discussed. Experiments were carried out on precracked concrete specimens of varying crack depths (0%-40% of the specimen thickness). Contact transducers were placed at the specimen surface with source and receiver separated by the crack. Tone-burst excitations over a freque...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Doboku Gakkai Ronbunshu

سال: 2000

ISSN: 0289-7806,1882-7187

DOI: 10.2208/jscej.2000.662_223