Evaluation of Biomedical Stainless Steels by Fretting Corrosion Test

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Corrosion Study of Grain-Refined 304L Stainless Steels Produced by the Martensitic Process

AISI 304L austenitic stainless steel with different grain sizes of 0.5 -12 μm was obtained through the martensitic process. Corrosion behavior of different samples was investigated in a 0.5M HCl solution using open circuit potential, potentiodynamic polarization and electrochemical impedance spectroscopy tests. Also, the correlation between the grain size and pitting corrosion resistance was as...

متن کامل

Fretting corrosion of tin-plated contacts: Evaluation of surface characteristics

The surface characteristics of the contact zone of tin-plated copper alloy contacts subjected to fretting motion for 8000, 16,800 and 48,000 cycles under unlubricated conditions are presented. The nature of the contact zone, at the verge of wearing out of the tin coating as well as upon the coating is completely worn out, is assessed using scanning electron microscopy (SEM), energy-dispersive X...

متن کامل

The Effect of Surface Roughness on the Fretting Corrosion of 316l Stainless Steel Biomaterial Surfaces

The medical device industry is still seeking answers to the mechanically-assisted corrosion (MAC) problem, which becomes increasingly important due to modularity in design. MAC manifests in various forms, some of which are fretting corrosion, crevice corrosion and stress corrosion. Several studies have been conducted to understand the causes and the factors that affect fretting corrosion. Some ...

متن کامل

Fretting Corrosion in Electric Contacts

Fretting corrosion is a form of accelerated atmospheric oxidation which occurs at the interface of contacting materials undergoing slight, cyclic relative motion. In electric contacts involving non-noble metals, fretting action can cause rapid increases in contact resistance, proceeding to virtual open circuits in a matter of minutes in the worst cases. Experimental results of resistance increa...

متن کامل

Evaluation of dissimilar joint properties of AISI316 to AISI430 stainless steels produced by GTAW

In this research, microstructure and mechanical properties of AISI316 to AISI430 dissimilar joint were investigated. For this purpose, GTAW process using ER316L and ER2209 filler metals with diameter of 2.4 mm was used. The microstructure and fracture surface of the welded samples were characterized by optical microscopy and scanning electron microscopy. Also the mechanical properties of the we...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Zairyo-to-Kankyo

سال: 1992

ISSN: 0917-0480,1881-9664

DOI: 10.3323/jcorr1991.41.399