Evaluation of Bal-Parikshan according to Harvard step test
نویسندگان
چکیده
منابع مشابه
Review Psychometric Parameters of the 29th Residency Test (1380) According to the Classic Test Theory (CTT)
Introduction. To select the best group, and to make a good decision, are of the most important worries of the health and medical education ministry and also all entrants in the residency test. Having and performing a reliable and good exam will reduce doubts to a great deal. Considering different scientific methods consist of (precisely review of curriculum by the designer committee, sampling o...
متن کاملCardiorespiratory endurance evaluation using heart rate analysis during ski simulator exercise and the Harvard step test in elementary school students
[Purpose] Efficient management using exercise programs with various benefits should be provided by educational institutions for children in their growth phase. We analyzed the heart rates of children during ski simulator exercise and the Harvard step test to evaluate the cardiopulmonary endurance by calculating their post-exercise recovery rate. [Subjects and Methods] The subjects (n = 77) were...
متن کاملMeasuring Physical Fitness and Cardiovascular Efficiency Using Harvard Step Test Approach under Fuzzy Environment
One may not be able to measure exactly the various parameters involved in computing physical fitness and cardiovascular efficiency of a human being. Inexactness, in turn, may lead to inaccurate results and misleading conclusions. In the present paper, using fuzzy arithmetic, we modify both the Long Form and in Short Form approach associated with the Harvard Step Test, under fuzzy environment. T...
متن کاملMaximal Step Test: A New Approach to Step Test Improvements
The purpose of this study was to introduce a new maximal step test (NMST) with adjusted step height based on the knee joint angle of 90°. Thirty female students of physical education With (Mean ± SD, ages: 23.6±2.11 yr, height: 164.63±7.14cm, weight: 60.97±4.01 kg, body fat percent: 23.6±2.11) participated in the study and performed both NMST and a maximal graded excise test (GXT) to measure ma...
متن کاملNovae and BAL QSOs: The Aluminum Test
Novae have been proposed as the explanation of high reported abundances of heavy elements in the gas producing the broad absorption lines (BALs) of QSOs. High abundances of odd numbered elements, including aluminum, are predicted. Available data contains hints that the Al/Si ratio may be high both in the BAL gas and in the broad emission line (BEL) gas. 1. Abundances in BAL QSOs Broad absorptio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: National Journal of Research in Ayurved Science
سال: 2019
ISSN: 2320-7329
DOI: 10.52482/ayurlog.v7i03.357