Evaluation of Badge-Type Diffusive Sampler Performance for Measuring Indoor Formaldehyde
نویسندگان
چکیده
منابع مشابه
Badge-type diffusive sampler using 3-methyl-2-benzothiazolinone hydrazone for measuring formaldehyde in indoor air.
The evaluation of a badge-type diffusive sampler for measuring formaldehyde using 3-methyl-2-benzothiazolinone hydrazone (MBTH) was investigated. On average, the formaldehyde concentration in blanks was reduced by approximately 31% by cleaning procedures. The cleaning techniques did not significantly differ in effectiveness. The maximum sampling rate was 22.4 +/- 3.5 mL min(-1) at MBTH concentr...
متن کاملEvaluation of a passive air sampler for measuring indoor formaldehyde.
A passive air sampler, using 4-amino-3-hydrazino-5-mercapto-1,2,4-triazole, was evaluated for the determination of formaldehyde in indoor environments. Chromatography paper cleaned using a 3% hydrogen peroxide solution was experimentally determined as being the optimum absorption filter for the collection of formaldehyde (0.05 microg cm(-2) formaldehyde). From a linear-regression analysis betwe...
متن کاملTOPAS / TDS D – Badge-Type Thermodesorption Passive Sampler Based on Tenax for Air Sampling - Development Study
The TOPAS / TDS D system combines the advantages of the passive sampling of badge-type passive samplers with thermal desorption for sample transfer to the gas chromatography system. The large surface and the sampler’s short diffusion path permit high sampling rates. Use of thermal desorption as a sample transfer technique avoids the necessity for time consuming sample preparation and allows low...
متن کاملEvaluation of Awareness, Performance and Side Effects of Formaldehyde Exposure
Background and purpose: Formaldehyde is used in operating rooms to disinfect and sterilize surgical instruments. Inhalation of formaldehyde gas causes various respiratory complications in people. Awareness on the use of formaldehyde can prevent many complications. This study was conducted to determine the level of knowledge and practice about formaldehyde exposure in the staff and students of t...
متن کاملFormaldehyde in the Indoor Environment
s Service (CAS). In 1944, Walker published the first edition of his classic work Formaldehyde.1 Between 1900 and 1930, formaldehyde-based resins became important * Author for correspondence. Address: Fraunhofer-Wilhelm-Klauditz-Institut (WKI), Department of Material Analysis and Indoor Chemistry, Bienroder Weg 54 E, 38108 Braunschweig, Germany. Phone: +49-531-2155-350. Fax: +49-531-2155-905. E-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Environmental Engineering Research
سال: 2013
ISSN: 1226-1025
DOI: 10.4491/eer.2013.18.3.123