Evaluation of Anterior Chamber Depth and Anterior Chamber Angle Changing After Phacoemulsification in the Primary Angle Close Suspect Eyes

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anterior chamber depth in open angle glaucoma.

Anterior chamber depth was measured in patients with primary open angle glaucoma, low tension glaucoma, pigmentary dispersion syndrome, and glaucoma suspects. Multiple linear regression analysis demonstrated that anterior chamber depth is a function of sex, age, and refractive error. Values for anterior chamber depth corrected for age and refractive error were greater in patients with pigmentar...

متن کامل

Assessment of the anterior chamber parameters after laser iridotomy in primary angle close suspect using Pentacam and gonioscopy.

AIM To evaluate the changes in the anterior segment parameters of the subjects with primary angle closure suspect (PACS) before and after laser iridotomy (LI) using the Pentacam and gonioscopy. METHODS Forty-eight eyes of 48 PACS were included. Anterior chamber angle (ACA), central anterior chamber depth (ACD), anterior chamber volume (ACV) and central corneal thickness (CCT) were recorded fr...

متن کامل

Anterior Chamber Angle Assessment Techniques

The anterior chamber angle is the actual anatomical angle created by the root of the iris and the peripheral corneal vault. Within it lie the structures involved in the outflow passage of the aqueous, namely the trabecular meshwork and the Schlemm’s canal (figure 1). The depth of the angle in a healthy eye is approximately 30°, with the superior part usually less deep than the inferior half. Ho...

متن کامل

anterior chamber depth changes after phacoemulsification and intraocular lens implantation

purpose: to determine anterior chamber depth (ac depth) changes during a 6 month period after phacoemulsification cataract surgery and foldable intraocular lens (iol) implantation. methods: in a cross-sectional study, 85 eyes of 85 patients were evaluated for ac depth and capsulo-rrhexis size one and six months after the procedure. results: patients included 44 male and 41 female subjects with ...

متن کامل

Anterior chamber depth in eyes with pseudoexfoliation.

The depth of the anterior chamber was measured in 34 eyes with pseudoexfoliation but without glaucoma and in 334 normal controls. No significant difference was found.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Open Access Macedonian Journal of Medical Sciences

سال: 2019

ISSN: 1857-9655

DOI: 10.3889/oamjms.2019.378