Evaluation of a Wipe Surface Sample Method for Collection of Bacillus Spores from Nonporous Surfaces
نویسندگان
چکیده
منابع مشابه
National validation study of a cellulose sponge wipe-processing method for use after sampling Bacillus anthracis spores from surfaces.
This work was initiated to address the gaps identified by Congress regarding validated biothreat environmental sampling and processing methods. Nine Laboratory Response Network-affiliated laboratories participated in a validation study of a cellulose sponge wipe-processing protocol for the recovery, detection, and quantification of viable Bacillus anthracis Sterne spores from steel surfaces. St...
متن کاملSwab Materials and Bacillus anthracis Spore Recovery from Nonporous Surfaces
Four swab materials were evaluated for their efficiency in recovery of Bacillus anthracis spores from steel coupons. Cotton, macrofoam, polyester, and rayon swabs were used to sample coupons inoculated with a spore suspension of known concentration. Three methods of processing for the removal of spores from the swabs (vortexing, sonication, or minimal agitation) and two swab preparations (premo...
متن کاملDevelopment of an aerosol surface inoculation method for bacillus spores.
A method was developed to deposit Bacillus subtilis spores via aerosolization onto various surface materials for biological agent decontamination and detection studies. This new method uses an apparatus coupled with a metered dose inhaler to reproducibly deposit spores onto various surfaces. A metered dose inhaler was loaded with Bacillus subtilis spores, a surrogate for Bacillus anthracis. Fiv...
متن کاملComposite Sampling of a Bacillus anthracis Surrogate with Cellulose Sponge Surface Samplers from a Nonporous Surface
A series of experiments was conducted to explore the utility of composite-based collection of surface samples for the detection of a Bacillus anthracis surrogate using cellulose sponge samplers on a nonporous stainless steel surface. Two composite-based collection approaches were evaluated over a surface area of 3716 cm2 (four separate 929 cm2 areas), larger than the 645 cm2 prescribed by the s...
متن کاملSurface Sampling Methods for Bacillus anthracis Spore Contamination
During an investigation conducted December 17-20, 2001, we collected environmental samples from a U.S. postal facility in Washington, D.C., known to be extensively contaminated with Bacillus anthracis spores. Because methods for collecting and analyzing B. anthracis spores have not yet been validated, our objective was to compare the relative effectiveness of sampling methods used for collectin...