Evaluation of a surface imaging system's isocenter calibration methods
نویسندگان
چکیده
منابع مشابه
Evaluation of a surface imaging system's isocenter calibration methods
AlignRT is a surface imaging system that has been utilized for localizing and tracking patient position during radiotherapy. AlignRT has two calibration procedures that can set the system's isocenter called "Monthly Calibration" (MC) and "Isocentre Calibration" (IC). The MC utilizes a calibration plate. In addition to the calibration plate, the IC utilizes a cubic phantom that is imaged with th...
متن کاملA Review on the Evaluation Methods of Health Information Systems
Evaluation of health information systems is an effective approach to ensure the efficacy of the system which can lead to the improvement in quality of health care services. The main aims of evaluation are to identify the strength and efficiency of system in health care delivery, to identify the weaknesses of the system, and to suggest general recommendations for improving the performance of the...
متن کاملinvestigation of single-user and multi-user detection methods in mc-cdma systems and comparison of their performances
در این پایان نامه به بررسی روش های آشکارسازی در سیستم های mc-cdma می پردازیم. با توجه به ماهیت آشکارسازی در این سیستم ها، تکنیک های آشکارسازی را می توان به دو دسته ی اصلی تقسیم نمود: آشکارسازی سیگنال ارسالی یک کاربر مطلوب بدون در نظر گرفتن اطلاعاتی در مورد سایر کاربران تداخل کننده که از آن ها به عنوان آشکارساز های تک کاربره یاد می شود و همچنین آشکارسازی سیگنال ارسالی همه ی کاربران فعال موجود در...
Comparative evaluation of niobium surface preparation methods for electrodeposition
To find a suitable treatment in the preparation of Nb surface for platinum electrodeposition, different methods such as thermal oxidation, anodic oxidation, mechanical roughening, and mechanical roughening with subsequent anodic etching were examined. X-ray photoelectron spectroscopy was used to study the chemical composition of depth analysis of the surface. Moreover, in order to examine the m...
متن کاملCalibration of Non-Conventional Imaging Systems
This thesis investigates the calibration of cameras that do not conform to the standard pinhole-plus-distortion camera model. The ability to calibrate such camera systems is essential for the development of new, non-conventional, camera types. The major contributions of the thesis are the development of calibration algorithms for both central catadioptric cameras and non-central flexible mirror...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Applied Clinical Medical Physics
سال: 2017
ISSN: 1526-9914
DOI: 10.1002/acm2.12054