Evaluation of a Novel Method for Grading Heart Murmur Intensity

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a novel method for grading heart murmur intensity.

OBJECTIVE To determine if heart murmur intensity grading performance can be improved using the heart sounds as an internal reference. METHODS Single-blind controlled trial of 100 medical students, residents, and pediatric attending physicians at a children's hospital. Groups of 1 to 3 participants were alternately assigned to intervention and control groups, reported their method of grading h...

متن کامل

A Novel Fuzzy Based Method for Heart Rate Variability Prediction

Abstract In this paper, a novel technique based on fuzzy method is presented for chaotic nonlinear time series prediction. Fuzzy approach with the gradient learning algorithm and methods constitutes the main components of this method. This learning process in this method is similar to conventional gradient descent learning process, except that the input patterns and parameters are stored in mem...

متن کامل

Response of heart murmur intensity to isometric (handgrip) exercise.

murs was evaluated in 36 patients and the results compared with the effects of amyl nitrite and phenylephrine. The isometric handgrip exercise produced immediate, reproducible, and significant increases in heart rate and blood pressure. It also increased the intensity of murmurs due to aortic and mitral regurgitation and mitral stenosis and attenuated the murmurs of left ventricular outflow tra...

متن کامل

A novel isolated dual perfusion/superfusion heart model for physiological and pharmacological evaluation of mammalian heart preparations

Abstract Introduction: Isolated perfused heart models such as perfusion and superfusion are commonly used for mammalian heart research. However, there are several fundamental limitations in the current techniques. In perfusion model, a suitable cannula is connected to the aorta and the perfusion is retrogradely performed. But, electrode displacement is a potential unwanted event resulted fr...

متن کامل

Endophthalmitis and a Heart Murmur.

A 48-year-old man, a heavy smoker and drinker, came to the emergency department complaining of pain, redness, and vision loss in his left eye (Figure A). Physical examination revealed a body temperature of 38.7 8C and hyperemic left conjunctiva. His oral hygiene was clearly poor and he was missing a number of teeth. Auscultation disclosed the presence of a systolic murmur at the left sternal bo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Archives of Pediatrics & Adolescent Medicine

سال: 2005

ISSN: 1072-4710

DOI: 10.1001/archpedi.159.4.329