Evaluation of a forced oscillation method to measure thoracic gas volume

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a forced oscillation method to measure thoracic gas volume.

The purpose of this study was to test a plethysmographic method of measuring thoracic gas volume (TGV) that, contrary to the usual panting method, would not require any active cooperation from the subject. It is based on the assumption that the out-of-phase component of airway impedance varies linearly with frequency. By using that assumption, TGV may be computed by combining measurements of to...

متن کامل

hazard evaluation of gas condensate stabilization and dehydration unit of parsian gas refinery using hazop procedures

شناسایی مخاطرات در واحد 400 پالایشگاه گاز پارسیان. در این پروزه با بکارگیری از تکنیک hazop به شناسا یی مخاطرات ، انحرافات ممکن و در صورت لزوم ارایه راهکارهای مناسب جهت افزایش ایمنی فرا یند پرداخته میگردد. شرایط عملیاتی مخاطره آمیز نظیر فشار و دمای بالا و وجود ترکیبات مختلف سمی و قابل انفجار در واحدهای پالایش گاز، ضرورت توجه به موارد ایمنی در این چنین واحدهایی را مشخص می سازد. مطالعه hazop یک ر...

Thoracic gas volume in early childhood.

A total body plethysmograph is descirbed which was used to study thoracic gas volume (TGV) in infants and young children from birth to 2 1/2 years, and was suitable for use even in very sick babies. Normal TGV values were obtained in 42 studies of 35 healthy infants and young children, and 16 children with abnormal lung volume are described. TGV correlated well with length, weight, chest circum...

متن کامل

A Simple Measure to Assess Hyperinflation and Air Trapping: 1-Forced Expiratory Volume in Three Second / Forced Vital Capacity

BACKGROUND Several recent studies have suggested that 1 minus-forced expiratory volume expired in 3 seconds / forced vital capacity (1-FEV3/FVC) may be an indicator of distal airway obstruction and a promising measure to evaluate small airways dysfunction. AIMS To investigate the associations of 1-FEV3/FVC with the spirometric measures and lung volumes that assess small airways dysfunction an...

متن کامل

a paradigm shift away from method-wise teaching to strategy-wise teaching: an investigation of reconstructive strategy versus communicative strategy

چکیده: هدف اصلی این مطالعه ی توصیفی تحقیقی در حقیقت تلاشی پساروش-گرا به منظور رسیدن به نتیجه ای منطقی در انتخاب مناسبترین راهکار آموزشی بر گرفته از چارچوب راهبردی مطرح شده توسط والدمر مارتن بوده که به بهترین شکل سازگار و مناسب با سامانه ی آموزشی ایران باشد. از این رو، دو راهکار آموزشی، راهکار ارتباطی و راهکار بازساختی، برای تحقیق و بررسی انتخاب شدند. صریحاً اینکه، در راستای هدف اصلی این پژوهش، ر...

15 صفحه اول

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Applied Physiology

سال: 1998

ISSN: 8750-7587,1522-1601

DOI: 10.1152/jappl.1998.84.3.862