Evaluation Method for Winding Performance of Distribution Transformer

نویسندگان

چکیده

In order to ensure the safe and stable operation of a power system, performance evaluation transformer windings after short-circuit test can predict whether are deformed in provide useful reference for maintenance sector. This paper proposes method evaluating improve overall effectiveness winding evaluation. The index data obtained based on impedance method, frequency response oscillation wave used algorithm proposed this paper. First, system is constructed. Second, weight each determined by analytic hierarchy process, then fuzzy comprehensive assessment introduced, matrix established, results calculated using formula. Finally, maximum membership principle determine level results, state obtained. example shows that measured be as “good”. Compared with traditional simplify while maintaining higher accuracy.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transient Voltage Distribution in Transformer Winding (experimental Investigation)

Abstract In this work, the non-liner voltage distribution in transformer winding is investigated that occurs due switching and lightning. Transformer winding is modeled in the alternative transients program (ATP) version of Electromagnetic transients program (EMTPRV). EMTP software is used to simulate the very fast transient overvoltage. An experimental setup that consist of , Recurrent surge g...

متن کامل

Characterization of Power Transformer Electromagnetic Forces Affected by Winding Faults

Electromagnetic forces in power transformer windings are produced by interaction between the leakage fluxes and current passing them. Since the leakage flux distribution along the windings height is in two axial and radial directions, so the electromagnetic forces have two components, radial and axial. There is a risk that a large electromagnetic force due to the short circuit or inrush current...

متن کامل

Transformer Models for Detection of Incipient Internal Winding Faults

A method of modeling internal turn-to-earth and turn-toturn faults in distribution transformer is discussed in this paper. The models are entirely compatible with the Alternative Transients Program(ATP). The simulation of the faults is based on known leakage factors between the various coils of the transformer. These leakage factors are evaluated by using a simple method implemented in this pap...

متن کامل

A High Frequency Transformer Winding Model for FRA Applications

Frequency response analysis (FRA) is a method which is used to detect mechanical faults in transformers. The FRA response of a transformer is determined by its geometry and material properties, and it can be considered as the transformer’s fingerprint. If there are any mechanical changes in the transformer, for example if the windings are moved or distorted, its fingerprint will also be changed...

متن کامل

A Method for Extracting Partial Discharge Signals in Transformer Winding with Wavelet Analysis

In this paper a method for extracting Partial Discharge (PD) signals is introduced, which is implemented for evaluating electrical measured partial discharges on a 66 kV / 25 MVA fully interleaved winding of a power transformer. Applying wavelet transform to a signal produces a wavelet detail coefficient distribution throughout the time-scale, which depends on the mother wavelet chosen. This me...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Energies

سال: 2021

ISSN: ['1996-1073']

DOI: https://doi.org/10.3390/en14185832