Evaluating the peak-to-valley dose ratio of synchrotron microbeams using PRESAGE fluorescence

Synchrotron-generated microbeam radiotherapy holds great promise for future treatment, but the high dose gradients present conventional dosimetry with a challenge. Measuring the important peak-to-valley dose ratio (PVDR) of a microbeam-collimated synchrotron source requires both a dosimeter and an analysis method capable of exceptional spatial resolution. The PVDR is of great interest since it ...

متن کامل

Reconstruction of human exposure to heavy metals using synchrotron radiation microbeams in prehistoric and modern humans.

OBJECTIVE Teeth can serve as records of environmental exposure to heavy metals during their formation. We applied a new technology - synchrotron radiation microbeams (SRXRF) - for analysis of heavy metals in human permanent teeth in modern and historical samples. METHODS Each tooth was cut in half. A longitudinal section 200 mum in thickness was subjected to the determination of the heavy met...

متن کامل

Evaluating the effect of Zinc Oxide nanoparticles doped with Gadolinium on dose enhancement factor by PRESAGE dosimeter

Background: New treatment modalities are developed with the aim of escalating tumor absorbed dose and simultaneously sparing the normal structures. The use of nanotechnology in cancer treatment offers some possibilities including destroying cancer tumors with minimal damage to healthy tissues. Zinc Oxide nanoparticles (ZnO NPs) are wide band gap semiconductors and seem to have a good effect on ...

متن کامل

Dose ratio proton radiography using the proximal side of the Bragg peak.

PURPOSE In recent years, there has been a movement toward single-detector proton radiography, due to its potential ease of implementation within the clinical environment. One such single-detector technique is the dose ratio method in which the dose maps from two pristine Bragg peaks are recorded beyond the patient. To date, this has only been investigated on the distal side of the lower energy ...

متن کامل

assessment of the efficiency of s.p.g.c refineries using network dea

data envelopment analysis (dea) is a powerful tool for measuring relative efficiency of organizational units referred to as decision making units (dmus). in most cases dmus have network structures with internal linking activities. traditional dea models, however, consider dmus as black boxes with no regard to their linking activities and therefore do not provide decision makers with the reasons...

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Synchrotron Radiation

سال: 2012

ISSN: 0909-0495,1600-5775

DOI: 10.1107/s0909049512005237