Evaluating Electromagnetic Interference of Communication Devices with Root ZX Mini Apex Locator
نویسندگان
چکیده
منابع مشابه
An in vivo evaluation of Root ZX electronic apex locator.
The Root ZX has been introduced recently as a device capable of performing accurately in the presence of sodium hypochlorite, blood, water, local anesthetic, and pulpal tissues. The Root ZX was used to locate the apical foramen in 26 root canals of vital teeth. After extraction of the teeth, a stereomicroscope was used to confirm visually the relationship of the tip of the endodontic file to th...
متن کاملThe accuracy of root canal measurements using the Mini Apex Locator and Root ZX-II: an evaluation in vitro.
OBJECTIVE The aim of this in vitro study was to compare the capacity of the Root ZX-II and Mini Apex Locator, electronic apex locators (EALS), to prevent overestimated working length. STUDY DESIGN Forty extracted human teeth were used for the study. The cervical portion of each canal was flared using Gates Glidden drills and the teeth were embedded in an alginate model. Canals were irrigated ...
متن کاملCalcium hydroxide dressing residues after different removal techniques affect the accuracy of Root-ZX apex locator
OBJECTIVES This study compared the ability of several techniques to remove calcium hydroxide (CH) from the root canal and determined the influence of CH residues on the accuracy of the electronic apex locator. MATERIALS AND METHODS Root canals of 90 human maxillary lateral incisors with confirmed true working length (TWL) were prepared and filled with CH. The teeth were randomly assigned to o...
متن کاملThe accuracy of the Root ZX electronic apex locator using stainless-steel and nickel-titanium files.
Numerous apex locator studies have been performed. Generally, they use only stainless-steel hand files for testing purposes. Today many clinicians use both stainless-steel and nickel-titanium files during the treatment of a case. Given the widespread use of nickel-titanium files, a comparison of the accuracy in determining length with an apex locator using stainless-steel and nickel-titanium fi...
متن کاملThe effect of different needle-insertion depths on the accuracy of the Root ZX II and Root ZX mini apex locators in the presence of various irrigants
BACKGROUND AND AIM: The aim of the present study was to evaluate the effect of different needle-insertion depths on the accuracy of the Root ZX II and Root ZX mini apex locators in the presence of various irrigants. METHODS: Ninety extracted single-canal human teeth were used in nine experimental groups. The coronal one-third of the canals was preflared, and the length to the major foramen was ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Dental Hypotheses
سال: 2016
ISSN: 2155-8213
DOI: 10.4103/2155-8213.195972