EURAMET supplementary comparison between INRiM, UME and PTB in Brinell hardness scales (HBW1/30 - HBW2.5/187.5) - EURAMET.M.H-S2.a.

نویسندگان

چکیده

Main text This report describes a EURAMET supplementary comparison in Brinell hardness scales of three national metrology institutes Italy, Turkey and Germany; INRiM, UME PTB, respectively. The pilot laboratory is INRiM the where two sets reference blocks for Hardness HBW1/30 HBW2.5/187.5 were used. Each set consists levels used each scales. was realized as planned Technical Protocol with some delay. measurement results uncertainty assessments declared by PTB are consistency other. To reach main this paper, click on Final Report . Note that which appears Appendix B BIPM key database kcdb.bipm.org/ final has been peer-reviewed approved publication CCM, according to provisions CIPM Mutual Recognition Arrangement (CIPM MRA).

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the INRIM and PTB lattice-spacing standards

To base the kilogram definition on the atomic mass of the Si atom, the present relative uncertainty of the Si lattice parameter must lowered to 3 × 10. To achieve this goal, a new experimental apparatus capable of a centimetre measurement-baseline has been made at the INRIM. The comparison between the determinations of the lattice parameter of crystals MO*4 of INRIM and WASO 4.2a of PTB is inte...

متن کامل

Comparison of air kerma-length product measurements between the PTB and the IAEA for x-radiation qualities used in computed tomography (EURAMET.RI(I)-S12, EURAMET project #1327)

A comparison of air kerma-length product determinations for standard radiation qualities defined for use in computed tomography (CT) was performed between the PTB and the IAEA as EURAMET project #1327, registered in the KCDB as the EURAMET.RI(I)-S12 comparison. A pencil type reference-class ionization chamber of the IAEA and the three RQT beam qualities established according to the IEC standard...

متن کامل

Optical-Fiber Power Meter Comparison Between NIST and PTB

We describe the results of a comparison of reference standards between the National Institute of Standards and Technology (NIST-USA) and National Institute of Metrology (NIM-China). We report optical fiber-based power measurements at nominal wavelengths of 1310 nm and 1550 nm. We compare the laboratories' reference standards by means of a commercial optical power meter. Measurement results show...

متن کامل

Bilateral Comparison of Buoyancy Artefacts between Ptb and Kriss

Buoyancy artefacts (BAs) are used for the experimental determination of air density. The artefacts used for this comparison were manufactured at the PTB and the KRISS respectively and consist of one hollow cylinder and one bobbin. Mass differences of the PTB and the KRISS BAs in vacuum and in air are measured simultaneously by using the PTB prototype mass comparator. Results of the bilateral co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Metrologia

سال: 2021

ISSN: ['0026-1394', '1681-7575']

DOI: https://doi.org/10.1088/0026-1394/58/1a/07003