Estimation of seismic resistance of multi-storey buildings based on a continuum model
نویسندگان
چکیده
A dynamic continuum plate model of a multi-story building is proposed in the form cantilevered orthotropic plate, developed framework Timoshenko’s theory plates, which describes seismic vibrations buildings. Formulas are given for determining reduced moduli elasticity, shear, and density building. Transverse natural forced oscillations nine-story under nine-point impacts considered. Numerical results obtained.
منابع مشابه
Reliability-based Seismic Assessment of Asymetric Multi-storey Buildings with Rc Shear Walls
The performance of buildings subjected to earthquake loads has shown that asymmetric structures are caused more extensive damages in comparison with symmetric structures. Hence, the seismic performance of asymmetric structures should be assessed due to future random earthquakes. Reliability-based seismic assessment as one of the tools in performance-based earthquake engineering has been introdu...
متن کاملInfluence of Masonry Infills Walls on the Seismic Behaviour of Multi-storey Waffle Slabs Rc Buildings
In this work, we analyze the influence of masonry infill walls on the seismic performance of waffle slabs reinforced concrete (RC) framed structures. We analyze buildings of three, five and eight storeys, which are representative for a big number of housings in Barcelona, Spain. Capacity spectra have been obtained by performing pushover analyses and we have used a simplified procedure to obtain...
متن کاملSeismic Behavior of One-Storey Gabion-Box Walls Buildings
Gabion-boxes, made with steel wire mesh and filled with stones of appropriated size, are normally stacked up one into another to form a retaining wall. Given their reduced costs and the easy availability of their constituting materials, gabion-box walls have been extensively used in developing countries (such as Nepal) also to realize simple one-storey residential buildings. In recent years, ma...
متن کاملOn-site greywater treatment and reuse in multi-storey buildings.
The paper presents a study of a pilot plant treating light greywater for seven flats. The pilot plant combines biological treatment (RBC) with physicochemical treatment (sand filtration and disinfection). The pilot plant produced effluent of excellent quality, meeting the urban reuse quality regulations, and was very efficient in TSS turbidity and BOD removal: 82%, 98% and 96%, respectively. CO...
متن کاملStudy on corollary of seismic base isolation system on buildings with soft storey
Soft storey buildings are characterized by having a storey which has a lot of open spaces. This soft storey creates a major weak point in an earthquake. Since soft stories are classically associated with retail spaces and parking garages, they are often on the lower stories of a building, which means that when they collapse, they can take the whole building down with them, causing serious struc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: E3S web of conferences
سال: 2023
ISSN: ['2555-0403', '2267-1242']
DOI: https://doi.org/10.1051/e3sconf/202340207019