Estimation of presampling modulation transfer function in synchrotron radiation microtomography
نویسندگان
چکیده
منابع مشابه
Image reconstruction from sparse data in synchrotron-radiation-based microtomography.
Synchrotron-radiation-based microcomputed-tomography (SR-μCT) is a powerful tool for yielding 3D structural information of high spatial and contrast resolution about a specimen preserved in its natural state. A large number of projection views are required currently for yielding SR-μCT images by use of existing algorithms without significant artifacts. When a wet biological specimen is imaged, ...
متن کاملSynchrotron radiation-based microtomography of alveolar support tissues.
OBJECTIVES To study the alveolar support structures using synchrotron radiation (SR)-based microtomography with particular focus on the alveolar surface. DESIGN High-resolution microtomography of jaw segments of various species and subsequent three-dimensional (3D) reconstruction. SETTING AND SAMPLE POPULATION Microtomography was performed at the DORIS-ring of the synchrotron facility of HA...
متن کاملinterpersonal function of language in subtitling
translation as a comunicative process is always said to be associated with various aspects of meaning loss or gain. subtitling as a mode of translating, due to special discoursal and textual conditions imposed upon it, is believed to be an obvious case of this loss or gain. presenting the spoken sound track of a film in writing and synchronizing the perception of this text by the viewers with...
15 صفحه اولSynchrotron-radiation Based Microtomography for In-vivo Corrosion Measurements of Magnesium Alloys
+*Witte, F; *Fischer, J; **Nellesen, J; **Crostack HA; ***Beckmann, F; *Windhagen, H +*Hannover Medical School, Hannover, Germany [email protected] INTRODUCTION: The in-vivo corrosion of magnesium alloys has the potential to provide a new mechanism which would allow degradable metal implants to be applied in musculoskeletal surgery [1]. This would particularly be true if magnesium alloys with pred...
متن کاملLandsat 7 on-orbit modulation transfer function estimation
The Landsat 7 spacecraft and its Enhanced Thematic Mapper Plus (ETM+) were launched on April 15, 1999. Pre-launch modeling of the ETM+ optical system predicted that modulation transfer function (MTF) performance would change onorbit. A method was developed to monitor the along-scan MTF performance of the ETM+ sensor system using on-orbit data of the Lake Pontchartrain Causeway in Louisiana. ETM...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
سال: 2010
ISSN: 0168-9002
DOI: 10.1016/j.nima.2010.03.111