Estimation of effective doses of radiation for patients with novel Coronavirus Disease Undergoing Chest CT scans.

نویسندگان

چکیده

ABSTRACT Evaluating the hazards and beneficiary of chest - CT imaging for patients COVID-19 Subjects Methods: A total number 160 suspected Covid-19 were classified into four groups (GP1(n=40) ,GP2(n=40) GP3(n=40)). The undergoing examination (Toshiba, Activion 16) .The acquisition protocols different as follows: GP 1 ((n=40), 100 Kv , ±15 mAs GP2 ((n=40) 120 150 ±20 mAs) GP3((n=40) Sure Exposure (SE), GP4((n=40) (SE)) . other parameters are (pitch=1.5; rotation time=0.75 sec; matrix size 512x512), All images reconstructed by Filtered Back Projection. Results:- CTDI volume were: (GP1: 7.8±0.09 mGy ; GP2: 26.4 ±0.25mGy; GP3: 16.8 ±4.7mGy; GP4: 5.5±0.1mGy P In contrast, CNR SNR insignificantly (P>0.05) among all groups. GP1and GP4 has a highly significant noise (P<0.05), in comparison with GP3. Conclusion: study demonstrates that performed kV protocol dose modulation (

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vital role of chest CT in diagnosis of coronavirus disease 2019 (COVID-19)

In December 2019, a new virus called coronavirus disease 2019 (COVID-19) causing severe acute respiratory syndrome emerged in Wuhan, China, and rapidly spread to other areas of China and other regions of the world. Since it was discovery, COVID-19 has spread to several countries and to this date, affecting about 2,329,651 people and caused about 160,721 deaths.  Since most COVID-19 infected cas...

متن کامل

Evaluation of radiation doses delivered in different chest CT protocols

BACKGROUND There are differences in the reference diagnostic levels for the computed tomography (CT) of the chest as cited in different literature sources. The doses are expressed either in weighted CT dose index (CTDIVOL) used to express the dose per slice, dose-length product (DLP), and effective dose (E). The purpose of this study was to assess the radiation dose used in Low Dose Computer To...

متن کامل

Radiation exposure in standard and high-resolution chest CT scans.

It has been suggested that radiation doses due to high-resolution computed tomography (HRCT) of the chest are considerably higher than those from conventional CT. We compared the effective dose (E, mSv) in conventional chest CT (10-mm contiguous slices) and HRCT (1.5-mm slices, gap 10 mm). In our study, the effective dose from a HRCT (0.98 mSv) is about 6.5 times less than the effective dose fr...

متن کامل

Very different external radiation doses in patients undergoing PET/CT or PET/MRI scans and factors affecting them.

Our aim was to determine the external radiation dose rates of patients undergoing positron emission tomography/computed tomography (PET/CT) and PET/magnetic resonance imaging (MRI) examinations, and to assess the factors affecting these doses. The external radiation dose rates (ERDR) from (18)F-FDG were measured using the Geiger-Müller tube at a distance of 10, 50, and 100cm from the patients' ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Arab Journal of Nuclear Sciences and Applications (Print)

سال: 2021

ISSN: ['2090-4258', '1110-0451']

DOI: https://doi.org/10.21608/ajnsa.2021.72242.1463