Estimating ASHRAE Guideline 36 energy savings for multi-zone variable air volume systems using Spawn of EnergyPlus
نویسندگان
چکیده
منابع مشابه
Variable Structure Behavioural Controller for Multi-agent Systems
In previous papers authors have considered agents as inertia-less self driven particles and designed a flocking algorithm. Application of this algorithm to agents with considerable inertial characteristics needs a behavioural controller. The controller uses the local information and helps every agent to imitate the desired behaviour as a member of the flocking frame which covers the main is...
متن کاملEstimating Energy Savings from Bus Improvement Options
The potential to achieve significant energy savings in the road transport sector can be a powerful driver to promote bus transport, especially bus rapid transit (BRT) development. This research introduces a spreadsheet tool for making realistic estimates of energy savings due to increased use of buses, with an explicit inclusion of the effect of congestion on traffic flow and fuel consumption. ...
متن کاملSuitability of ASHRAE Guideline 14 Metrics for Calibration
We introduce and provide results from a rigorous, scientific testing methodology that allows pure building model calibration systems to be compared fairly to traditional output error (e.g. how well does simulation output match utility bills?) as well as input-side error (e.g. how well, variable-by-variable, did the calibration capture the true building's description?). This system is then used ...
متن کاملSimulation of Energy Use in Uk Supermarkets Using Energyplus
This paper investigates the interaction between supermarket heating, ventilation and air conditioning and refrigeration systems through simulation in EnergyPlus. This interaction has been studied by modelling a generic UK supermarket. The impact on the sum of HVAC and refrigeration energy consumption due to changes in a range of operating conditions was studied. These include the effect of alte...
متن کاملOptimal design of onboard energy storage systems with volume limitation for urban electrical rail transportation
Train braking energy regeneration in urban electrical rail transportation systems can reduce energy consumption and operational cost of the system. In this paper, optimal design of an onboard energy storage system (OESS) with volume constraint is presented for urban electrical rail transportation systems (ERTS). Onboard super-capacitors are considered as the storage system. The objective functi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Building Performance Simulation
سال: 2022
ISSN: ['1940-1507', '1940-1493']
DOI: https://doi.org/10.1080/19401493.2021.2021286