Estimating and correcting interference fringes in infrared spectra in infrared hyperspectral imaging
نویسندگان
چکیده
منابع مشابه
estimating soil organic carbon using hyperspectral data in visible, near-infrared and shortwave-infrared (vis-nir-swir) range
background and objectives: soil organic carbon is a main soil property and particularly important for development and sustainable management of agricultural systems. soil organic matter content, which is typically measured in the form of soil organic carbon soc content, is commonly regarded as a key indicator of soil quality and utilization (liu et al., 2015). the presence of som has been prove...
متن کاملA chemometric method for correcting Fourier transform infrared spectra of biomaterials for interference from water in KBr discs.
Mid-infrared (mid-IR) analysis of solid biomaterials by the familiar KBr disc technique is all too often frustrated by water interference in the very important protein (amide) and carbohydrate (hydroxyl) regions of their spectra. A method was therefore devised that overcomes the difficulty and corrects IR spectra of solid biomaterials in KBr discs by mathematically eliminating the interference ...
متن کاملNear-Infrared Spectra of Ultraluminous Infrared Galaxies.
Near-infrared spectra with a resolution of lambda&solm0;Deltalambda approximately 1100 in the rest-wavelength range of 1.8-2.2 µm have been obtained for a complete sample of 33 ultraluminous infrared galaxies (ULIRGs). Of the 33 objects observed, two show evidence of a central active galactic nucleus (AGN) through either a broad Paschen-alpha line or emission in the 1.963 µm fine structure of [...
متن کاملInfrared Imaging Devices in Infrared Medical Radiography.
The word “thermograph” often used to describe both an instrument and the product of that instrument has as its roots the Greek words thermos and gruphos. The latter means a sketch or pictorial representation; thus, the graphic arts, scientific graphs, photographs, etc. The former relates to heat or temperature. At first reading, then, the word “thermograph” is most appropriate for a graphical r...
متن کاملInfrared Hyperspectral Imaging Results from Vapor Plume Experiments
In this article, recent measurements made with LIFTIRS, the Livermore Imaging Fourier Transform InfraRed Spectrometer, are presented. The experience gained with this instrument has produced a variety of insights into the tradeoffs between signal to noise ratio (SNR), spectral resolution and temporal resolution for time multiplexed Fourier transform imaging spectrometers. This experience has als...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Analyst
سال: 2018
ISSN: 0003-2654,1364-5528
DOI: 10.1039/c8an00093j