Estimating afterload, systemic vascular resistance and pulmonary vascular resistance in an intensive care setting

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Systemic vascular resistance: an unreliable index of left ventricular afterload.

Systemic vascular resistance (SVR) is a frequently used clinical index of left ventricular afterload. However, SVR may not adequately assess left ventricular afterload (i.e., ventricular internal fiber load during systole) since it reflects only peripheral vasomotor tone. In contrast, left ventricular end-systolic wall stress (sigma es) reflects the combined effects of peripheral loading condit...

متن کامل

Pulmonary vascular resistance.

where P represents the pressure gradient between the pulmonary artery and the pulmonary vein, F, the blood flow per unit time, and R. the vascular resistance. For a given pressure gradient and flow rate, R will be determined, among other things, by the physical dimensions of the chaniiels that the blood traverses. In a rigid hydraulic system this formula applies over a wide range of flow and pr...

متن کامل

Pulmonary Vascular Resistance

where P represents the pressure gradient between the pulmonary artery and the pulmonary vein, F, the blood flow per unit time, and R. the vascular resistance. For a given pressure gradient and flow rate, R will be determined, among other things, by the physical dimensions of the chaniiels that the blood traverses. In a rigid hydraulic system this formula applies over a wide range of flow and pr...

متن کامل

Pulmonary vascular resistance in emphysema.

To assess the hemodynamic effects of pulmonary microvasculature disruption in emphysema, we examined resting pulmonary hemodynamics and lung function in 12 carefully identified patients with type A chronic obstructive pulmonary disease. Individuals with respiratory muscle weakness and intercurrent infection were excluded. Standard spirometry, helium dilution lung volumes, and single-breath carb...

متن کامل

Systemic vascular resistance should be banned.

In an article published in a recent issue of CHEST (June 2014), Marik 1 mentioned, “In patients with septic shock who are fl uid responders (an increase in cardiac output with fl uid boluses), vasodilatation with a fall in systematic vascular resistance has been observed.... Hence, although the cardiac output increases, vasodilatation occurs.” I believe that this statement is erroneous because ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IFAC Proceedings Volumes

سال: 2012

ISSN: 1474-6670

DOI: 10.3182/20120829-3-hu-2029.00112