Establishment of normal reference ranges for glycemic variability in Chinese subjects using continuous glucose monitoring
نویسندگان
چکیده
منابع مشابه
Establishment of normal reference ranges for glycemic variability in Chinese subjects using continuous glucose monitoring
BACKGROUND Glycemic variability is increasingly recognized as an important issue in diabetes management. However, the lack of normative values may limit its applicability in the clinical setting. The objective of this study was to establish preliminary normal reference ranges for glycemic variability by analyzing continuous glucose monitoring (CGM) data obtained from healthy Chinese adults. M...
متن کاملReference Values for Continuous Glucose Monitoring in Chinese Subjects
OBJECTIVE The widespread clinical application of continuous glucose monitoring (CGM) is limited by the lack of generally accepted reference values. This multicenter study aims to establish preliminary normal reference values for CGM parameters in a sample of healthy Chinese subjects. RESEARCH DESIGN AND METHODS A total of 434 healthy individuals with normal glucose regulation completed a 3-da...
متن کاملGlycemic Variability Percentage: A Novel Method for Assessing Glycemic Variability from Continuous Glucose Monitor Data
BACKGROUND High levels of glycemic variability are still observed in most patients with diabetes with severe insulin deficiency. Glycemic variability may be an important risk factor for acute and chronic complications. Despite its clinical importance, there is no consensus on the optimum method for characterizing glycemic variability. METHOD We developed a simple new metric, the glycemic vari...
متن کاملGlyCulator: a glycemic variability calculation tool for continuous glucose monitoring data.
Glycemic variability has become a major concern over the years as growing evidence is gathered on its detrimental impact on the risk of diabetes complications. Glycated hemoglobin, although ubiquitous in clinical practice, does not adequately summarize short-term glycemic variability. This gap may be addressed through the use of continuous glucose monitoring, which continuously estimates glycem...
متن کاملAccuracy of Continuous Glucose Monitoring Measurements in Normo-Glycemic Individuals
BACKGROUND The validity of continuous glucose monitoring (CGM) is well established in diabetic patients. CGM is also increasingly used for research purposes in normo-glycemic individuals, but the CGM validity in such individuals is unknown. We studied the accuracy of CGM measurements in normo-glycemic individuals by comparing CGM-derived versus venous blood-derived glucose levels and measures o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Medical Science Monitor
سال: 2011
ISSN: 1234-1010
DOI: 10.12659/msm.881318