Establishing metrological traceability for radiometric calibration of earth observation sensor in Malaysia
نویسندگان
چکیده
منابع مشابه
Selection of a Radiance Source for the Radiometric Calibration Facility at the CSIRO Earth Observation Centre
This report discusses the selection of a radiance source suitable for calibrating a diverse group of radiometers commonly used in CSIRO. The chosen system is based on an integrating sphere that enables the mapping of incident radiance against instrument response with known uncertainty. Commercially available candidate source systems are assessed against the physical and radiometric characterist...
متن کاملMetrological Timelines in Traceability
There is a growing requirement for an internationally accepted system of recognition of measurement capabilities and relationships within and among countries, to facilitate seamless global commerce and trade. As a result, metrologists worldwide have recently developed increased interest in the concept and definition of traceability. Classically, traceability provides a way of relating the resul...
متن کاملReference Spectrometry for Calibration of Optical Earth Observation Systems
A small palm-sized, reference spectrometer, mounted on a remote controlled model helicopter is being developed and tested to provide calibrated reference data for optical Earth Observation systems by the National Physical Laboratory (NPL) in conjunction with City University in London. The spectrometer is traceable to NPL’s primary standard cryogenic radiometer. The traceability chain includes t...
متن کاملRadiometric Calibration for AgCam
The student-built Agricultural Camera (AgCam) now onboard the International Space Station observes the Earth surface through two linescan cameras with Charge-Coupled Device (CCD) arrays sensitive to visible and near-infrared wavelengths, respectively. The electro-optical components of the AgCam were characterized using precision calibration equipment; a method for modeling and applying these me...
متن کاملRadiometric Calibration Methodology of the Landsat 8 Thermal Infrared Sensor
The science-focused mission of the Landsat 8 Thermal Infrared Sensor (TIRS) requires that it have an accurate radiometric calibration. A calibration methodology was developed to convert the raw output from the instrument into an accurate at-aperture radiance. The methodology is based on measurements obtained during component-level and instrument-level characterization testing. The radiometric a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IOP Conference Series: Materials Science and Engineering
سال: 2016
ISSN: 1757-8981,1757-899X