Establishing action levels for EPID-based QA for IMRT
نویسندگان
چکیده
منابع مشابه
Establishing action levels for EPID‐based QA for IMRT
Although portal dosimetry is used to provide quality assurance (QA) for intensity-modulated radiation therapy (IMRT) treatment plans, trends in agreement between the portal dose prediction (PDP) and the measured dose have not been clarified. In this work, we evaluated three scalar parameters of agreement for 152 treatment plans (1152 treatment fields): maximum gamma (gamma max), average gamma (...
متن کاملSU-E-T-164: Clinical Implementation of ASi EPID Panels for QA of IMRT/VMAT Plans.
PURPOSE To investigate various issues for clinical implementation of aSi EPID panels for IMRT/VMAT QA. METHODS Six linacs are used in our clinic for EPID-based plan QA; two Varian Truebeams, two Varian 2100 series, two Elekta Infiniti series. Multiple corrections must be accounted for in the calibration of each panel for dosimetric use. Varian aSi panels are calibrated with standard dark fiel...
متن کاملInvestigation of error detection capabilities of phantom, EPID and MLC log file based IMRT QA methods
A patient specific quality assurance (QA) should detect errors that originate anywhere in the treatment planning process. However, the increasing complexity of treatment plans has increased the need for improvements in the accuracy of the patient specific pretreatment verification process. This has led to the utilization of higher resolution QA methods such as the electronic portal imaging devi...
متن کاملPixel response‐based EPID dosimetry for patient specific QA
Increasing use of high dose rate, flattening filter free (FFF), and/or small-sized field beams presents a significant challenge to the medical physics community. In this work, we develop a strategy of using a high spatial resolution and high frame rate amorphous silicon flat panel electronic portal imaging device (EPID) for dosimetric measurements of these challenging cases, as well as for conv...
متن کامل3D EPID-based in vivo dosimetry for IMRT and VMAT
In this paper the various approaches of EPID-based in vivo IMRT and VMAT dose verification, and their clinical implementation, are described. It will be shown that EPID-based in vivo dosimetry plays an important role in the total chain of verification procedures in a radiotherapy department. EPID-based dosimetry, in combination with in-room imaging, is a fast and accurate tool for 3D in vivo ve...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Applied Clinical Medical Physics
سال: 2008
ISSN: 1526-9914
DOI: 10.1120/jacmp.v9i3.2721