Erratum: Readout Electronics for Spatial Distribution Measurement of Neutron Beam Flux in BNCT

نویسندگان

چکیده

Abstract Boron neutron capture therapy (BNCT) is a promising cancer treatment that selectively destroys tumor cells using beam. However, accurately and fast measuring the spatial distribution of flux critical to ensuring effective treatment. To address this challenge, Micromegas detectors are applied for first time measure beam in BNCT. Due high flux, large area, multiple components BNCT beam, design readout electronics can handle counting rate, channel numbers, integration, discrimination challenging. This paper proposes targeted system overcome challenge. A modular structure based on PCI Express (PXIe) platform designed 384-channel readout. fully parallel developed shaper parameters optimized achieve rate each channel. multi-channel high-speed, large-capacity caching technique high-speed data storage problem. Digital shapers implemented field-programmable gate array (FPGA) integration. Tests demonstrate support 800 kHz an excellent position resolution 1.4 mm. Furthermore, final tests confirm our successfully different components.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Epithermal Neutron Beam Generator Design for Bnct

BNCT is a radiotherapy modality based on the neutron capture and fission reactions that occur when boron-10 is irradiated by thermal neutrons. This reaction generates alpha and lithium that produce high density of ionizations in close to the reaction site. The concept provides high absorbed doses into the cancerous cells preserving the adjacent healthy tissues. Nowadays, the available neutron s...

متن کامل

Evaluation of a Neutron Beam Generation Facility for the Accelerator-Based BNCT

The important things in designing facilities for BNCT are to obtain neutron beams with appropriate energy spectrum and intensity for efficient treatment. In recent years, at several universities, accelerator-based BNCT facilities were designed, which are composed of target and beam shaping assembly to generate epithermal neutron beams[1]. As a previous study, target system[2][3] and a beam shap...

متن کامل

Feasibility of the.utilization of BNCT in the fast neutron therapy beam at Fermilab

The Neutron Therapy Facility at Fermilab has treated cancer patients since 1976. Since then more than 2,300 patients have been treated and a wealth of clinical information accumulated. The therapeutic neutron beam at Fermilab is produced by bombarding a beryllium target with 66 MeV protons. The resulting continuous neutron spectrum ranges from thermal to 66 MeV in neutron energy. It is clear th...

متن کامل

Analog Front-end Electronics for Beam Position Measurement on the Beam Halo Measurement

Enhancements have been made to the log-ratio analog front-end electronics based on the Analog Devices 8307 logarithmic amplifier as used on the LEDA accelerator. The dynamic range of greater than 85 dB, has been extended to nearly the full capability of the AD8307 from the previous design of approximately 65 dB through the addition of a 350 MHz band-pass filter, careful use of ground and power ...

متن کامل

The Readout Electronics for Silicon Tracker of the GLAST Beam Test Engineering Model

The design of the Gamma-ray Large Area Space Telescope (GLAST) pairconversion tracker is based upon single-sided silicon-strip detectors with 36 cm long strips. The electronics used to read out this system are based upon CMOS ASICs and are similar in many ways to electronics used in high energy physics experiments. However, stringent requirements on power consumption and reliability, which are ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Instrumentation

سال: 2023

ISSN: ['1748-0221']

DOI: https://doi.org/10.1088/1748-0221/18/07/e07001