Erratum: Linear and nonlinear magnetic error measurements using action and phase jump analysis [Phys. Rev. ST Accel. Beams12, 014002 (2009)]
نویسندگان
چکیده
منابع مشابه
synthesis of amido alkylnaphthols using nano-magnetic particles and surfactants
we used dbsa and nano-magnetic for the synthesis of amido alkylnaphtols.
15 صفحه اولDesign, Analysis and Simulation of a Linear Phase Distributed Amplifier
In this paper a new method for the design of a linear phase distributed amplifier in 180nm CMOS technology is presented. The method is based on analogy between transversal filters and distributed amplifiers topologies. In the proposed method the linearity of the phase at frequency range of 0-50 GHz is obtained by using proper weighting factors for each gain stage in cascaded amplifier topology....
متن کاملProviding comprehensive control chart for monitoring of linear and nonlinear profiles using functional data analysis.
Considering profiles as functional variables, two control charts are proposed for their monitoring in phase II. Due to its conformity with the nature of real-world profiles, applying functional model leads to proposed control charts obtained through functional data analysis techniques with desired features. These include simplicity in calculation and possibility of using them for different prof...
متن کاملMeasurements and Error Analysis
The complete statement of a measured value should include an estimate of the level of confidence associated with the value. Properly reporting an experimental result along with its uncertainty allows other people to make judgments about the quality of the experiment, and it facilitates meaningful comparisons with other similar values or a theoretical prediction. Without an uncertainty estimate,...
متن کاملSingle-shot electron bunch length measurements using a spatial electro-optical autocorrelation interferometer.
A spatial, electro-optical autocorrelation (EOA) interferometer using the vertically polarized lobes of coherent transition radiation (CTR) has been developed as a single-shot electron bunch length monitor at an optical beam port downstream the 100 MeV preinjector LINAC of the Swiss Light Source. This EOA monitor combines the advantages of step-scan interferometers (high temporal resolution) [D...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Physical Review Special Topics - Accelerators and Beams
سال: 2010
ISSN: 1098-4402
DOI: 10.1103/physrevstab.13.059901