Erratum for “Ultimate Static Strength of Plate Girders from Tests”
نویسندگان
چکیده
منابع مشابه
ultimate flexural strength of plate girders under the effect of weld crack in flange toe
the plate girders are used in important structural systems. the earlier design of plate girders was restricted to their critical bukling capacity. experimental and theoretical studies show the plate girders with vertical stiffners can carry load over than their critical buckling loads and then in modern design codes is permitted to use post- buckling capacity of them. in this case the out- of- ...
متن کاملModel Studies on Plate Girders
Tests on eighteen small scale models which simulate the elastic and post-buckling behaviour of plate girders when subjected to shear loading are reported and discussed. Themodels were fabricated of steel and Araldite; the major aim was to assess whether small scale models can be employed to study shear buckling problems. A secondary object was to examine whether araldite could be used for predi...
متن کاملA Proposed Method to Evaluate Ultimate Resistance of Plate Girders Subjected to Shear and Patch Loading (RESEARCH NOTE)
Experimental investigation of the ultimate resistance of slender, steel-plate girder web panels to combined shear-and-patch loading indicates significant interaction between shear loading and patch loading. However, an existing interaction formula is based on experimental results. Herein, an improved design procedure for slender plate girders subjected to combined shear and patch loading is pro...
متن کاملDesign Requirements for Plate Girders with Bolted Transverse Stiffeners
The web of plate girders in bridges are usually reinforced by welded transverse stiffeners in order to improve their shear capacity.Due to problems associated with field welding and fatigue, welded stiffeners are not suitable for retrofitting existing bridges. Bolted stiffeners are a practical alternative for strengthening girders that are expected to experience shear stress in excess of their ...
متن کاملStrength-Flow Parameters of Loose Silty Sands From Piezocone Tests
Piezocone penetration tests with dissipation phases are particularly useful for geotechnical site characterization. They also provide three independent readings with depth from a single sounding as well as time-rate information. In past investigations, only silty sands with specific silt content have been tested and complete sets of tests have not been conducted to evaluate the influence of dif...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Structural Division
سال: 1975
ISSN: 0044-8001,2690-3377
DOI: 10.1061/jsdeag.0004016