Erratum for “Single-Port Suction Manifolds”
نویسندگان
چکیده
منابع مشابه
Design and Performance of a Multi-Port Robotic Suction Gripper
This paper presents the mechanical-workings and gripping performance characteristics of a vacuum-based robotic gripper. The gripper uses multiple ports with attached commercial suction cups to grasp objects from a variety of directions using suction power. The valves remain closed until opened by a hinge-based mechanism, in order to eliminate vacuum leakage. The ability for the valves to be act...
متن کاملPort-Hamiltonian systems on discrete manifolds
This paper offers a geometric framework for modeling port-Hamiltonian systems on discrete manifolds. The simplicial Dirac structure, capturing the topological laws of the system, is defined in terms of primal and dual cochains related by the coboundary operators. This finitedimensional Dirac structure, as discrete analogue of the canonical Stokes-Dirac structure, allows for the formulation of f...
متن کاملSingle Port Laparoscopic Gastrostomy
Introduction: Since the first classic descriptions of surgical gastrostomies for feeding by supraumbilical medial incisions, patients were operated under general anesthesia, with prolonged time of surgery, these were patients in poor health status, undernourished due to inadequate intake or to neurological or tumor involvement, with prolonged hospitalization, both for the recovery of the intest...
متن کاملSingle Port Donor Nephrectomy
In 2007, Rane presented the first single port nephrectomy for a small non-functioning kidney at the World Congress of Endourology. Since that time, the use of single port surgery for nephrectomy has expanded to include donor nephrectomy. Over the next two years the technique was adopted for many others types of nephrectomies to include donor nephrectomy. We present our technique for single port...
متن کاملSingle port manipulator for minimally invasive surgery
INTRODUCTION Although minimally invasive surgery has many advantages compared to open surgery, its performance is restricted due to technical limitations. Besides the development of new instruments, the current focus is set on trauma reduction by performing single port operations or transluminal surgery (NOTES) [1]. The development of instruments with enhanced flexibility is a major challenge a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Hydraulics Division
سال: 1967
ISSN: 0044-796X,2690-2524
DOI: 10.1061/jyceaj.0001578